1.

FLASHCARD QUESTION

Front

A pneumatic valve is defined as a “5/3-valve”. What do the numbers 5/3 mean in this definition?

Back

The valve has 5 ports and 3 switching positions.

2.

FLASHCARD QUESTION

Front

What is the use of end position cushioning of a double-acting cylinder, as shown below?

Media Image

Back

It prevents a hard striking of the piston at the end positions.

3.

FLASHCARD QUESTION

Front

In the clamp application, the system has to perform a cycle of five steps. The clamp close cylinder (gripper) 2A extends to grab the part and then the system stops. Which of the following components is the possible cause of malfunction? (It can be assumed, that the PLC program is working properly.) Options: Clamp extend cylinder 1A, Magnetic reed switch sensor 1B1, Magnetic reed switch sensor 1B2, Flow control valve 1V2, Inductive sensor 2B2

Media Image

Back

Inductive sensor 2B2

4.

FLASHCARD QUESTION

Front

In a lift and transfer application, as shown below, a part is transferred on a motor driven traverse axis carriage. At the end of travel position the carriage is stopped. Cylinder 2A extends to lift the part. Next cylinder 1A extends to move the part onto the next station. If cylinder 1A fails to retract, what is the possible cause? Options: Flow control valve 1V2 is fully open., Flow control valve 1V3 is fully open., Solenoid 1M2 of directional control valve 1V1 is energized., Air pressure is present at port 1 of directional control valve 1V1., No air pressure is present at port 2 of directional control valve 1V1.

Media Image

Back

No air pressure is present at port 2 of directional control valve 1V1.

5.

FLASHCARD QUESTION

Front

The table below shows an overview about the common technical characteristics of a pneumatic actuator. The table belongs to a …

Media Image

Back

single-acting cylinder.

6.

FLASHCARD QUESTION

Front

Using the circuit below, if valve 1V2 is clogged, what will happen?

Media Image

Back

The cylinder will extend but not retract.

7.

FLASHCARD QUESTION

Front

What could be the possible cause of the malfunction in the pneumatic control circuit where output Q5.3 is switched on and Cylinder 1A does not extend? Options: 1M1 of directional control valve 1V1, Cylinder 1A, Adjustable one-way flow control valve 1V2, Sensor 1S2, Adjustable one-way flow control valve 1V3

Media Image

Back

1M1 of directional control valve 1V1

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?