FLASHCARD QUESTION
Front
A pneumatic valve is defined as a “5/3-valve”. What do the numbers 5/3 mean in this definition?
Back
The valve has 5 ports and 3 switching positions.
2.
FLASHCARD QUESTION
Front
What is the use of end position cushioning of a double-acting cylinder, as shown below?
Back
It prevents a hard striking of the piston at the end positions.
3.
FLASHCARD QUESTION
Front
In the clamp application, the system has to perform a cycle of five steps. The clamp close cylinder (gripper) 2A extends to grab the part and then the system stops. Which of the following components is the possible cause of malfunction? (It can be assumed, that the PLC program is working properly.) Options: Clamp extend cylinder 1A, Magnetic reed switch sensor 1B1, Magnetic reed switch sensor 1B2, Flow control valve 1V2, Inductive sensor 2B2
Back
Inductive sensor 2B2
4.
FLASHCARD QUESTION
Front
In a lift and transfer application, as shown below, a part is transferred on a motor driven traverse axis carriage. At the end of travel position the carriage is stopped. Cylinder 2A extends to lift the part. Next cylinder 1A extends to move the part onto the next station. If cylinder 1A fails to retract, what is the possible cause? Options: Flow control valve 1V2 is fully open., Flow control valve 1V3 is fully open., Solenoid 1M2 of directional control valve 1V1 is energized., Air pressure is present at port 1 of directional control valve 1V1., No air pressure is present at port 2 of directional control valve 1V1.
Back
No air pressure is present at port 2 of directional control valve 1V1.
5.
FLASHCARD QUESTION
Front
The table below shows an overview about the common technical characteristics of a pneumatic actuator. The table belongs to a …
Back
single-acting cylinder.
6.
FLASHCARD QUESTION
Front
Using the circuit below, if valve 1V2 is clogged, what will happen?
Back
The cylinder will extend but not retract.
7.
FLASHCARD QUESTION
Front
What could be the possible cause of the malfunction in the pneumatic control circuit where output Q5.3 is switched on and Cylinder 1A does not extend? Options: 1M1 of directional control valve 1V1, Cylinder 1A, Adjustable one-way flow control valve 1V2, Sensor 1S2, Adjustable one-way flow control valve 1V3
Back
1M1 of directional control valve 1V1