IFGC FINAL

IFGC FINAL

Assessment

Flashcard

Professional Development

Professional Development

Hard

Created by

Quizizz Content

FREE Resource

Student preview

quiz-placeholder

50 questions

Show all answers

1.

FLASHCARD QUESTION

Front

Appliances shall not be installed in a location subject to vehicle damage except____________.

Back

where protected by an approved means

2.

FLASHCARD QUESTION

Front

Where the air-infiltration-rate is unknown, a room or space providing indoor combustion air requires a minimum volume of __________ cubic feet per 1,000 Btu/h of the appliance input rating.

Back

50

3.

FLASHCARD QUESTION

Front

Openings obtaining indoor combustion air from a different story require a total minimum free area of_________ square inch(es) per 1,000 Btu/h of the total input rating of appliances.

Back

2

4.

FLASHCARD QUESTION

Front

Where a space is provided outdoor combustion air through two openings, one opening must begin within _________ inches of the top and within ____________inches of the bottom of the enclosure.

Back

12, 12

5.

FLASHCARD QUESTION

Front

Within dwelling units, unobstructed _____________ are permitted to convey combustion air.

Back

stud and joist spaces

6.

FLASHCARD QUESTION

Front

Where vehicles are capable of passing under an appliance installed in a public garage, the appliance shall be installed a minimum of ________________ inches higher than the tallest vehicle garage door opening.

Back

12

7.

FLASHCARD QUESTION

Front

Condensate waste and drain lines shall be not less than ________________ -inch internal diameter.

Back

¾