608/014 Mock Exam 2

608/014 Mock Exam 2

Assessment

Quiz

Physics

KG - University

Medium

Used 24+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

Which standard must test leads comply with in order to help avoid electric shock when undertaking fault finding and diagnosis work?
G.N. 3
BS 7671
GS38
BS 3036

2.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

Which document must be completed when replacing an existing faulty fan isolator switch?
An Electrical Installation Certificate
A Condition Report
An Electrical Installation Condition Report
A Minor Electrical Installation Works Certificate

3.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

Who would an operative need to keep informed of serious faults found on the lighting circuits in a fully functioning commercial unit?
Manufacturers of the test instruments
Specialist equipment manufacturers
The HSE
The clients or their representatives

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

What fault would an experienced operative suspect if the final socket-outlet on a radial circuit was not operating but the rest of the outlets on the circuit were?
Open circuit at the origin of the circuit
Short circuit at the origin of the circuit
Open circuit at the final socket-outlet
Short circuit at the final socket-outlet

5.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

What is the most likely reason for a 15 A re-wireable fuse, protecting a radial socket outlet circuit that is reported to 'blow' every so often.
Transient overvoltage
Open circuit in the line
Occasional overloading
Poor metering at the intake

6.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

What precautions would an inspector need to consider when undertaking fault diagnosis work to stairway lighting, in an occupied multi-storey building that has back up supplies?
Ensure that the emergency lights are functioning correctly
Ensure the risk assessments are completed and followed
Ensure the standby generators are connected to the DNO supply
Ensure that all access equipment is non-metallic and tagged as 'safe'.

7.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

What is the correct unit that would be displayed on an RCD tester when confirming compliance with additional protection?
mA
In
ms
m