UPC Chapter 6

UPC Chapter 6

12th Grade - University

55 Qs

quiz-placeholder

Similar activities

1st Semester Review - SC09

1st Semester Review - SC09

8th - 12th Grade

58 Qs

Unit 1 Review

Unit 1 Review

9th - 12th Grade

56 Qs

Class v. Class Interim Review

Class v. Class Interim Review

8th - 12th Grade

52 Qs

Environmental Science Chapters 4 and 5 Review

Environmental Science Chapters 4 and 5 Review

11th - 12th Grade

50 Qs

APES Unit 7 Review

APES Unit 7 Review

11th Grade - University

56 Qs

Hydrology: water cycle & currents

Hydrology: water cycle & currents

5th Grade - University

51 Qs

Earth Science Midterm Review

Earth Science Midterm Review

9th - 12th Grade

54 Qs

5th Grade EOG Science Review #2

5th Grade EOG Science Review #2

KG - University

57 Qs

UPC Chapter 6

UPC Chapter 6

Assessment

Quiz

Other Sciences

12th Grade - University

Medium

Used 68+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

55 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The code requirement for "an adequate supply of potable running water" is for ______.
Cleansing and sanitation
Protection of trap seals
Water-cooled equipment
Hydronic systems

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The primary reason for installing backflow prevention assemblies is to ______.
Prevent excessive pressure
Prevent mixing of hot and cold water
Prevent pollution or contamination of the potable water supply
Prevent scalding

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Ballcocks in water closet tanks shall be installed so that the critical level of the water inlet is above the full opening of the overflow pipe at least ______ inch(es).
1/2
1
3
6

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The minimum height of the atmospheric vacuum breaker above the highest part of a urinal equipped with a flushometer valve:______ inch(es).
1
3
6
12

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The minimum height of the atmospheric vacuum breaker above the overflow rim of a vat: ______ inch(es).
1
2
6
12

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The minimum height of the atmospheric vacuum breaker above all downstream piping for lawn sprinkler system atmospheric vacuum breakers: ______ inch(es).
1
6
12
24

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

PEX tubing shall not be installed within the first ______ inches of piping connected to a water heater.
12
18
24
36

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?