What is the proper description for the structure labeled as 'B' in the attached image? What do you think it is?

Introduction to Ultrasound

Quiz
•
Specialty
•
Professional Development
•
Easy
Used 328+ times
FREE Resource
6 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
isoechoic; thyroid gland
hyperechoic; connective tissue
hypoechoic; lymph node
anechoic; blood vessel
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following transducers would be best for imaging the carotid artery in the neck? Be sure you can explain your answer.
the high frequency linear transducer
the lower frequency curvilinear transducer
the lower frequency phased array
an intracavitary transducer
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The attached image of a patient's right kidney was obtained by placing the transducer on the patient's right side in the coronal plane. As is the usual convention, the probe marker was pointing toward the patient's head. The screen marker is indicated by the green dot in the image.
Which directions on the patient's body correspond to arrow A and B on the image, respectively?
A points superiorly, B points inferiorly.
A points laterally (toward patient's right), B points inferiorly.
A points medially (toward patient's left), B points superiorly.
None of the above.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The attached color Doppler image shows an artery and adjacent vein. Which of the following statements is correct?
The vessel to the right in the image is the artery because it is red.
The vessel to the left in the image is the vein because it is blue.
Blood in the vessel to the right of the image is flowing toward the transducer.
The absolute velocity of blood flow determines whether the lumen of the vessel appears blue or red.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
You are interested in evaluating the structure labeled with an 'x' in the attached image. Which control should be adjusted to best optimize the image?
depth
focal point
gain
time gain compensation
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Following examination of a patient, a student placed the ultrasound transducer in the probe holder as shown. What did the student do incorrectly?
The student failed to clean the transducer with an approved wipe after use.
The student failed to clean the transducer with an approved wipe after use and should have placed the transducer facing down.
Nothing. Transducers are expected to look like this after use.
Similar Resources on Quizizz
11 questions
ad-PIE

Quiz
•
Professional Development
10 questions
PKT APRIL 2023

Quiz
•
Professional Development
11 questions
POCUS

Quiz
•
Professional Development
10 questions
Basic Mechanical Ventilation

Quiz
•
University - Professi...
10 questions
Head-to-Toe Assessment

Quiz
•
University - Professi...
10 questions
Cardiac EMT Quiz (Valentine's Day 2024)

Quiz
•
Professional Development
10 questions
PN2350: Ethics Review

Quiz
•
University - Professi...
10 questions
MeOH Quiz

Quiz
•
Professional Development
Popular Resources on Quizizz
15 questions
Multiplication Facts

Quiz
•
4th Grade
25 questions
SS Combined Advisory Quiz

Quiz
•
6th - 8th Grade
40 questions
Week 4 Student In Class Practice Set

Quiz
•
9th - 12th Grade
40 questions
SOL: ILE DNA Tech, Gen, Evol 2025

Quiz
•
9th - 12th Grade
20 questions
NC Universities (R2H)

Quiz
•
9th - 12th Grade
15 questions
June Review Quiz

Quiz
•
Professional Development
20 questions
Congruent and Similar Triangles

Quiz
•
8th Grade
25 questions
Triangle Inequalities

Quiz
•
10th - 12th Grade