1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following valves has the type of gland packing box that may need to be repacked after a long period or regular use ?
A. Spherical plug type drain off valve
B. Double check valve
C. Float operated valve
D. Stop valve
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The warning pipe from a cold water storage cistern must be fitted ?
A. Lower than the float valve
B. Higher than the float valve
C. On the opposite side of the cistern
to the float valve
D. Level with the float valve
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The warning pipe from a Domestic Cold Water Storage Cistern must be terminated ?
A. A warning pipe is not required
B. Outside the building
C. Inside the building
D. Over the heating cold feed and
expansion cistern
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A plastic Domestic Cold Water Storage Cistern should be ?
A. Supported with batons under the base
B. Supported over the entire area of the
base with hardboard
C. Supported over the entire area of the
base with chipboard
D. Supported over the entire area of the
base with floor boarding or ply
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A plastic Domestic Cold Water Storage Cistern should ?
A. Be fitted with an airtight lid
B. Only needs a lid if in a dirty location
C. Be fitted with a tight fitting lid with a
screened vent
D. Be fitted with a loose fitting lid
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The New Water Regulations require that an isolation valve to a domestic cold water supply pipe from a storage cistern should be fitted ?
A. As near to the cistern outlet as possible
B. A valve is not required
C. In the airing cupboard
D. In the most convenient position if fitted
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
In which of the following section of pipe-work is water hammer likely to happen ?
A. Cold feed to storage cistern in loft
B. Cold feed to sink tap
C. Hot supply to sink tap
D. Underground cold water supply pipe