1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

If the EPA regulations change after a technician has been certified

the technician will be "grandfathered" into the new changes

this will only affect technicians who have not yet been certified

it is the technicians responsibility to comply with all future changes

this will only affect technicians who have been certified after January 1, 2000

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Why is it easier to have air enter gaskets and fittings on a low pressure system than on a high pressure system?

because air is attracted to R-11 and R-123 more than to R-12 and R-22

because a low pressure system operates in a vacuum

because low pressure systems often use a centrifugal compressor

because low pressure systems often use gaskets that are semi-permeable

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

At what pressure does a rupture disk open on a low pressure system?

10 psig

15 psig

20 psig

25 psig

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the easiest way to leak test a low pressure system?

connect your gauges and add 15 psig of nitrogen

connect your gauges and add 150 psig of nitrogen with a trace amount of R-22

Add warm water over the coils until you reach 10 psig

recover all refrigerant, then pull the system down to a 500 micron vacuum and see if the vacuum holds

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Why is it important not to exceed 10 psig when leak testing a low pressure system?

Because the relief valve on the reciever would blow

Because the condenser test pressure is 10 psig max.

because the rupture disc on the evaporator could fail

because the shaft seals cannot withstand more than 10 psig without leaking

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

When using an electronic leak detector, where is a water box leak tested after the water has been removed?

at the drain valve

at the rupture disk

at the inlet valve

at the shaft seal

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is used when leak testing a water tube on a low pressure chiller?

a hydrometer

a psychrometer

a manometer

a hydrostatic tube test kit

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?