1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The net pressure or net head is defined as ______ at it's rated capacity and rated RPM for the pump.

what the pump is producing

what the discharge gauge pressure is reading

what the water supply is producing

what the pump supply pressure is

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

To evaluate a fire pump's performance during the initial installation acceptance test, a curve that consists of the flow rate data obtained during testing is compared to _____.

the fire pump manufacturer's supplied curve

a curve from similar fire pump installations

a curve supplied by the insurance company

a curve from the building owner

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

The net output (or net pressure) is determined by _____.

subtracting suction pressure from discharge pressure readings

adding suction and discharge pressures together

dividing discharge pressure by the suction pressures

multiplying the suction and discharge pressures

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

The feet-head relationship can be described as follows: If you pit 1 lb. of water into a long, narrow vertical tube, the water would rise to a height of approximately ____ feet.

2.31

.433

10

231

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

A pitot tube or "playpipes" can be used for flow testing during a fire pump test, by placing a pitot qauge in the stream of water produced. The pressure reading produced by the pitot qauge is ______ pressure.

pitot

qauge

suction

static

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

According to the presentation, 1 cubic foot of water weighs about _______ lbs.

12.1

62.4

100

144

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

For a passing fire pump acceptance test, the pump must produce at least _____% of rated head at 150%.

25

50

65

100

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?