Pneumatic Troubleshooting Mod 7- Systems

Pneumatic Troubleshooting Mod 7- Systems

Professional Development

16 Qs

quiz-placeholder

Similar activities

Ω Deliveries 3

Ω Deliveries 3

Professional Development

11 Qs

HSE Life Saving Rules

HSE Life Saving Rules

Professional Development

15 Qs

ระบบ Distribution Transformer 315 kVA(Recycle Water System)

ระบบ Distribution Transformer 315 kVA(Recycle Water System)

Professional Development

14 Qs

Post Test Sosialisasi RSD dan HSSE FT Reo

Post Test Sosialisasi RSD dan HSSE FT Reo

Professional Development

20 Qs

Confirmation of Learning 3

Confirmation of Learning 3

Professional Development

20 Qs

CPL Acft Tech - Fuel & the Fuel System

CPL Acft Tech - Fuel & the Fuel System

Professional Development

15 Qs

THERMODYNAMICS

THERMODYNAMICS

University - Professional Development

17 Qs

Starbucks Quiz 5

Starbucks Quiz 5

University - Professional Development

20 Qs

Pneumatic Troubleshooting Mod 7- Systems

Pneumatic Troubleshooting Mod 7- Systems

Assessment

Quiz

Other

Professional Development

Practice Problem

Medium

Created by

Shannon Honeycutt

Used 16+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

16 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A regulator can cause a low pressure condition if it has a mechanical problem or if___________________.

It has been mis-adjusted

It is oversized

Its element is clogged

Its drain is open

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A closed exhaust restrictor will prevent an actuator from moving by __________________.

Blocking the inlet port to the actuator

Exhausting excessive air to atmosphere

Blocking the DCV’s spool

Preventing air from leaving the actuator

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A flow chart is based on the ___________________ method of troubleshooting

Symptom and cause

Output-back

Shotgun

Input-Forward

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Slow actuator speed is commonly caused by ____________________.

Flow control valves

An increase in the pressure differential across the actuator

Non-venting regulators

High pressure

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When an actuator moves out of sequence the __________________ is usually the cause.

Control circuit

Pneumatic components

Hydraulic components

Component settings

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The PLC’s ___________________ can aid troubleshooting because they can be compared to the PLC’s program to correct sequencing.

Terminals

Indicators

Relays

Dip switches

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A zero pressure condition occurs due to problems with compressors, _______________, and air leaks.

Lubricators

Exhaust restrictors

Regulators

Quick exhaust valves

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?