1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a preferred frequency as outlined in BS7671?

40 Hz

50 Hz

60 Hz

400 Hz

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

120 volts Dc between conductors is classified as

Extra low voltage

Reduced low voltage

Low voltage

Medium voltage

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where protection against overload is provided by a semi-enclosed (rewireable) fuse to as 3036, the current rating of the cable must be at least

0.725 times the current rating of the fuse

The nominal current rating of the fuse divided by 0.725

The same rating as the design current of the circuit

0.725 times the design current of the circuit

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following does not have to be considered in relation to the connection between conductors or between a conductor and other equipment?

The material of the conductor and its insulation

The number and shape of the wires forming the conductor

The number of conductors to be connected together

The type of overcurrent device protecting the cable

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following cannot be used as an earth electrode?

Underground structural metalwork embedded in foundations

Metalwork installed in the foundations

Earth plates or pipes

Metallic water utility supply pipe

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where a final circuit is intended to supply one or more items of equipment, such that the total protective conductor current is likely to exceed 10 mA and the protective conductor is mechanically protected, the minimum csa for a single copper conductor should be which of the following?

2.5 mm2

4.0 mm2

6.0 mm2

10 mm2

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The required test voltage for an insulation resistance test of an installation operating at a nominal voltage of 400 V is?

250VAC

500VAC

500 V DC

1000V DC

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?