Flamephotometry

Flamephotometry

University

10 Qs

quiz-placeholder

Similar activities

Acids and Bases

Acids and Bases

University

12 Qs

Chapter 12​  ​ Liquids, Solids, ​ and Intermolecular Forces​

Chapter 12​ ​ Liquids, Solids, ​ and Intermolecular Forces​

University

15 Qs

Bonding

Bonding

8th Grade - University

11 Qs

CLINICAL CHEMISTRY MODULE 5

CLINICAL CHEMISTRY MODULE 5

University

15 Qs

Bunsen Burner

Bunsen Burner

KG - University

11 Qs

Measurements

Measurements

University - Professional Development

10 Qs

ANACHE24A Post Lecture Quiz - 032223

ANACHE24A Post Lecture Quiz - 032223

University

12 Qs

Colloid & Surface Chemistry Quiz

Colloid & Surface Chemistry Quiz

University

10 Qs

Flamephotometry

Flamephotometry

Assessment

Quiz

Chemistry

University

Medium

Created by

Jayesh Dhalani

Used 33+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In Flame photometry, Flame color’s intensity tells about

how much of the element present

Number of compound present

complex structure of compound

none of above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Flame photometry is mainly used for,

1st and 2nd group elements

3rd and 4th group elements

Whole periodic table

none of this

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The elements like gold, silver, & inert gases are not analyzed by flame photometry because

They need higher amount of energy for excitation than 1st and 2nd group.

They need lesser amount of energy for excitation than 1st and 2nd group.

not related to energy

depends on molecular weight

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is the principle of Flame emission photometers?

Radiation is absorbed by non-excited atoms in vapour state and are excited to higher states

Medium absorbs radiation and transmitted radiation is measured

Colour and wavelength of the flame is measured

Only wavelength of the flame is measured

5.

FILL IN THE BLANK QUESTION

1 min • 1 pt

In Flame emission photometers, the measurement of _____________ is used for qualitative analysis.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In Flame emission photometers, the measurement of _____________ is used for quantitative analysis.

Colour

Intensity

Velocity

Frequency

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is disadvantage of Laminar flow burner used in Flame photometry?

Noiseless

Stable flame for analysis

Efficient atomization of sample

Sample containing two or more solvents can be burned efficiently

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?