Ref CH2

Ref CH2

Professional Development

7 Qs

quiz-placeholder

Similar activities

Utilities Fuctional Meeting 2020

Utilities Fuctional Meeting 2020

Professional Development

8 Qs

unit 24 part 1

unit 24 part 1

Professional Development

8 Qs

Thermostatic Expansion Valves TEV TXV

Thermostatic Expansion Valves TEV TXV

Professional Development

9 Qs

Condenser

Condenser

Professional Development

10 Qs

KS_HVAC_intermediate

KS_HVAC_intermediate

Professional Development

10 Qs

Lubrication systems review 1

Lubrication systems review 1

Professional Development

10 Qs

Refrigeration

Refrigeration

Professional Development

10 Qs

hvac

hvac

Professional Development

10 Qs

Ref CH2

Ref CH2

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Shawn Goulet

Used 7+ times

FREE Resource

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The low side of a vapor compression cycle contains the:

Condenser

Compressor discharge line

Evaporator

Condenser and evaporator

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The boiling point of refrigerant in the condenser is the same as:

Evaporator temperature

Compressor suction temperature

Condensing temperature

Condensing pressure

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Of the following items the largest amount of heat removal in BTU’s for one pound of water is:

Its sensible heat

Its latent heat of fusion

Its latent heat of vaporization

Its latent heat of melting

4.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

If the evaporator in a vapor compression cycle is not cold enough, it can be made colder by:

Raising the evaporator pressure

Stopping the compressor temporarily

Lowering the evaporator pressure

Venting the refrigerant to the atmosphere

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

The purpose or the condenser in the vapor compression cycle is to:

Save the refrigerant for re-use

Reduce the superheated vapor to evaporator temperature

Reduce the evaporator pressure

Lower the condenser pressure

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

In the vapor compression cycle, the compressor:

Heats the refrigerant vapor

Reduces the evaporator pressure

Compresses the refrigerant vapor

All of the above

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Water can be made to boil at 50 degrees by:

Subcooling it to 50°F

Reduce the pressure to 14.7 psi absolute

Placing it under a high enough vacuum

Lowering the pressure to atmospheric pressure