OREDE-P RGTP Unit 35: Open Rack Vaporizer

OREDE-P RGTP Unit 35: Open Rack Vaporizer

Professional Development

7 Qs

quiz-placeholder

Similar activities

trial

trial

Professional Development

10 Qs

OREDE-P RGTP Unit 60 : Fuel Gas System

OREDE-P RGTP Unit 60 : Fuel Gas System

Professional Development

5 Qs

Trivia on the Ocean Pollution

Trivia on the Ocean Pollution

Professional Development

10 Qs

SAL UT 03 Water purification methods

SAL UT 03 Water purification methods

Professional Development

8 Qs

Sistem Transportasi Gas

Sistem Transportasi Gas

Professional Development

10 Qs

anaphy lab quiz sec a

anaphy lab quiz sec a

Professional Development

10 Qs

OREDE-P RGTP Unloading, Reloading and GUCD

OREDE-P RGTP Unloading, Reloading and GUCD

Professional Development

11 Qs

OREDE-P RGTP Unit: 65 Seawater System

OREDE-P RGTP Unit: 65 Seawater System

Professional Development

9 Qs

OREDE-P RGTP Unit 35: Open Rack Vaporizer

OREDE-P RGTP Unit 35: Open Rack Vaporizer

Assessment

Quiz

Science, Physics, Chemistry

Professional Development

Medium

Created by

faris shakir

Used 5+ times

FREE Resource

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main purpose of ORV in the Regas system?

To increase NG pressure up to 65 barg.

ORV is used to recover any BOG generation in the Regas system without flaring.

Vaporizers are used for one of two basic purposes: to generate a vapor or to transfer heat from seawater to LNG.

ORV is used to maintain pressure and temperature of send out based on nomination.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the heating medium used in the ORV system at RGTP?

Industrial propane

Glycol

Seawater

Natural air draft

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum different temperature control for seawater outfall from ORV ?

9'C

7'C

10'C

8'C

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many ORV in operation when sendout nomination is 500 ton/hr?

1

2

3

4

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the metering system, we have 3 individual runs to measure outgoing flow using USM. What is the maximum capacity for each run?

359 mmscfd

300 mmscfd

259 mmscfd

500 mmscfd

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At RGTP we have 4 Gas Chromatography for quality check purposes. There is the specific location for the GC at RGTP except:

Trucking Facilities

Metering System

Flare System

BOG return Header

7.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

When Gas Chromatography at Bog Return Header is used?


You may choose more than one answer

Normal Operation

Unloading/Reloading activity

Trucking activities

GUCD