OREDE-P RGTP Unit: 65 Seawater System

OREDE-P RGTP Unit: 65 Seawater System

Professional Development

9 Qs

quiz-placeholder

Similar activities

Volumetric & Gravimetric Method

Volumetric & Gravimetric Method

Professional Development

9 Qs

Thermal and nuclear power generation

Thermal and nuclear power generation

Professional Development

10 Qs

stress and strain

stress and strain

Professional Development

10 Qs

Hydroelectricity

Hydroelectricity

6th Grade - Professional Development

8 Qs

EMA PD - Engineering Software and Tools

EMA PD - Engineering Software and Tools

9th Grade - Professional Development

10 Qs

Car Air Bag System

Car Air Bag System

Professional Development

9 Qs

Science Physics Express 1: Measurement_Micrometer Screw Gauge

Science Physics Express 1: Measurement_Micrometer Screw Gauge

Professional Development

10 Qs

pp7 Central Heating Pipework Installation Quiz

pp7 Central Heating Pipework Installation Quiz

Professional Development

13 Qs

OREDE-P RGTP Unit: 65 Seawater System

OREDE-P RGTP Unit: 65 Seawater System

Assessment

Quiz

Physics

Professional Development

Easy

Created by

faris shakir

Used 5+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of seawater from discharge seawater pump?

To wash ORV

Heating medium to vaporize LNG

To remove debris

Cooling medium LNG

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is function of Travelling Band Screen

To collect debris using mesh panels

To Catch Fish

To generate hypochlorite

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum temperature difference between the intake and discharge of seawater

40 °C

3 °C

7 °C

15 °C

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of sodium hypochlorite?

To protect seawater system from marine growth

To clean electrolyzer rod

To neutralize pH waste sump pit

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Caustic soda solution using for

Remove corrosion at Electrolytic rod

To neutraliz chemical waste sump pit

Using for cleaning degassing tank

To dilute Hydrogen

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the chemical use for cleaning Electrolytic Generator

Ammonia

Uric acid

Hydrochloric Acid

Uranium

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of Electrolyzer Generator unit?

To generate clean seawater

To generate Sodium Hypochlorite

To generate Caustic Acid

To generate Sodium hydroxide

8.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Marine Bio fouling will shorten the life of pumps, screens, heat exchangers and other plant items as well as increase the operation and maintenance costs. Wich of bio fouling Marco Organism should be remove from seawater?

Mussels

Alge

Clams

Bacteria

Bacteriophage

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the concentration of Continuous Dosing range and maximum Shock Dosing?

0.1-0.7 and 1.3

0.1-0.2 and 0.5

0.2-0.7 and 1.0

0.2-0.5 and 0.6