Review Unit 7 part 2

Review Unit 7 part 2

University

45 Qs

quiz-placeholder

Similar activities

RAC Test No. 1- Basic Refrigeration Cycle

RAC Test No. 1- Basic Refrigeration Cycle

University

40 Qs

UAS ILMU BAHAN TEKNIK 2022-2023

UAS ILMU BAHAN TEKNIK 2022-2023

University

40 Qs

LATIHAN US TKRO

LATIHAN US TKRO

10th Grade - University

50 Qs

Test z angličtiny B1

Test z angličtiny B1

University

41 Qs

physical disabilties

physical disabilties

University

48 Qs

Raman_Reti_3

Raman_Reti_3

KG - Professional Development

50 Qs

Review Questions

Review Questions

University

40 Qs

Review unit 4 part 2

Review unit 4 part 2

University

47 Qs

Review Unit 7 part 2

Review Unit 7 part 2

Assessment

Quiz

Special Education

University

Medium

Created by

Makki Al-Marhoon

Used 13+ times

FREE Resource

AI

Enhance your content

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

45 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

Refer to the sequential control simulator schematic diagram, what happen when tank 2 reaches high level and LS2 opened?

CR8 energized and CR9,CR2 de-energized and starting pump 2

CR8 de-energized and CR9,CR2 energized and starting pump 2

CR6 de-energized and CR4 and C1 stop the pump 1

SV2 stop the pump 2

2.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

Refer to the schematic diagram of sequential control simulator, what happen when pushing PB5c?

LS21a opens, de-energizing CR6, CR4 & C1 and stop pump 1

CR4 energizes, SV1 operate, C1 energizes and pump 1 start

CR9 energizes, SV1 operate, C1 energizes and pump 1 start

CR1 energizes, SV1 operate, C1 energizes and pump 1 start

3.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

Refer to the schematic diagram of sequential control simulator. The sequence is started, what happen when tank 2 reaches HI level?

LS21a opens, de-energizing CR6, CR4 & C1 and stop pump 1

CR4 energizes, SV1 operate, C1 energizes and pump 1 start

TS2 opens, CR8 de-energizes, then CR9 & C2 energize and pump 2 start

CHTR energizes and heats the product in tank 2

4.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

Refer to the schematic diagram of sequential control simulator .The sequence is started, what happen when timer TDE1 energized?

LS21a opens, de-energizing CR6, CR4 & C1 and stop pump 1

CR4 energizes, SV1 operate, C1 energizes and pump 1 start

CHTR energizes and heats the product in tank 2

TS2 opens, CR8 de-energizes, then CR9 & C2 energize and pump 2 start

5.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

Refer to the schematic diagram of sequential control simulator. The sequence is started, what happen when the product heated?

LS21a opens, de-energizing CR6, CR4 & C1 and stop pump 1

CR4 energizes, SV1 operate, C1 energizes and pump 1 start

CHTR energizes and heats the product in tank 2

TS2 opens, CR8 de-energizes, then CR9 & C2 energize and pump 2 start

6.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

Refer to the schematic diagram of sequential control simulator, what is the function of LS31a?

To stop pump 1

To start pump 2

To stop pump 2

To stop pump 3

7.

MULTIPLE CHOICE QUESTION

15 mins • 1 pt

In the sequenced control simulator, when the system will give abnormal alarms during the process?

Presser Switch (PS )activated

Solenoid valve control the product

The product transferred to other tank

Shut down

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?