Structural

Structural

Professional Development

20 Qs

quiz-placeholder

Similar activities

Professional Practice: RA 9266

Professional Practice: RA 9266

KG - Professional Development

25 Qs

BLDG. LAWS Q3 - PD 1096

BLDG. LAWS Q3 - PD 1096

Professional Development

15 Qs

Rule 7 & 8 (1)

Rule 7 & 8 (1)

Professional Development

25 Qs

ALE PD 1096

ALE PD 1096

Professional Development

25 Qs

Cloud Riders Of Rohan

Cloud Riders Of Rohan

Professional Development

16 Qs

Repaso pre examen ord. Residencial

Repaso pre examen ord. Residencial

Professional Development

15 Qs

Building Laws Quiz 5 & 6- BP220 & PD 957

Building Laws Quiz 5 & 6- BP220 & PD 957

KG - Professional Development

25 Qs

Construction

Construction

Professional Development

20 Qs

Structural

Structural

Assessment

Quiz

Architecture

Professional Development

Hard

Created by

Brian Tapispisan

Used 524+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is a structural system without complete vertical local carrying space frame. (NSCP 208.20)

Bearing Wall System

Non-Bearing Wall System

Loaded Wall System

Uniform Wall System

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Is a component including its attachments having fundamental period less than or equal to 0.06 sec. (NSCP 208.20)

Rigid Component

Flexible Component

Control Component

Lunged Component

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Is a component including its attachments having fundamental period greater than 0.60 sec. (NSCP 208.20)

Rigid Component

Flexible Component

Control Component

Lunged Component

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Concrete filled driven piles of uniform section shall have a nominal outside diameter of not less than (NSCP 307.7.3)

150mm

175mm

200mm

300mm

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum bend diameter for 10mm Ø through 25mm Ø bars (NSCP 407.30)

5 db

6 db

8 db

10 db

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum bend diameter for 28mm Ø through 36mm Ø bars (NSCP 407.30)

5 db

6 db

8 db

10 db

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum clear spacing between parallel bars in a layer must be db but not less than? (NSCP 407.7.3)

13mm

25mm

50mm

20mm