Team 2 Ice Breaker

Team 2 Ice Breaker

1st - 10th Grade

10 Qs

quiz-placeholder

Similar activities

Distance, Rate and Time

Distance, Rate and Time

5th - 7th Grade

11 Qs

Ratio

Ratio

6th Grade

15 Qs

changes around us

changes around us

1st Grade

10 Qs

Force and Motion

Force and Motion

5th Grade

10 Qs

Ratio

Ratio

7th - 8th Grade

10 Qs

Real Life Fractions

Real Life Fractions

5th Grade

8 Qs

Mr. Winstead's 9 weeks test review materials id

Mr. Winstead's 9 weeks test review materials id

9th - 12th Grade

13 Qs

Speed, I Am Lightning McQueen!

Speed, I Am Lightning McQueen!

8th - 9th Grade

10 Qs

Team 2 Ice Breaker

Team 2 Ice Breaker

Assessment

Quiz

Mathematics, Chemistry

1st - 10th Grade

Medium

Created by

Samuel Grebialde

Used 1+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

SPECIFIC GRAVITY/DENSITY & FINENESS OF CEMENT

The glass, circular, and graduated container used in the test for the Density of Hydraulic Cement

Erlenmeyer Flask

Graduated Cylinder 50 mL capacity

Le Chatelier Flask

Ceramic Crucible

2.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

SPECIFIC GRAVITY/DENSITY & FINENESS OF CEMENT

Temperature at which the Le Chatelier Flask is immersed

950+-50 deg celsius

50 deg celsius

25 deg celsius

Room Temperature

3.

FILL IN THE BLANK QUESTION

30 sec • 1 pt

In the standard procedures for laboratory safety, it is important to examine the MSDS before handling chemicals. What does MSDS stand for?

4.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

The corresponding mixer speed for the following settings are:

Slow Speed: 120±5rpm

Medium Speed: 265±10rpm

Slow Speed: 130±5rpm

Medium Speed: 275±10rpm

Slow Speed: 140±5rpm

Medium Speed: 285±10rpm

Slow Speed: 150±5rpm

Medium Speed: 295±10rpm

5.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

The temperature that is to be maintained in the Moist or Cabinet Room

Temperature : 24.0 ± 2.0°C

Relative Humidity : not less than 90%

Temperature : 23.0 ± 2.0°C

Relative Humidity : not less than 95%

Temperature : 23.0 ± 4.0°C

Relative Humidity : not less than 95%

Temperature : 24.0 ± 4.0°C

Relative Humidity : not less than 90%

6.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

The height of drop of the flow table when testing for flow of blended hydraulic cement

10mm

12.7mm

1.5cm

2.0cm

7.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

The autoclave expansion test is for determining the _______

soundness of Portland cement

malleability of cement mortar

consistency of Portland cement

hardness

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?