Search Header Logo

Q3-Electrical Motor Control

Authored by shafie 34

Professional Development

3rd - 4th Grade

Used 9+ times

Q3-Electrical Motor Control
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

Which of the following devices is not categorized as a control equipment or devices in a starter unit?

pushbutton switch.

thermal overload relay.

selector switch.

timer relay.

2.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

Which of the following procedures is not true about a remote switch?

        

It provides an automatic ON/OFF cycles of a starter unit.

It is connected in a main circuit of a starter unit.

There normally connected in series to each other in a control circuit.

It is operate due to setting point of temperature, level, flow or pressure.

3.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

A no-volt coil protection in the starter unit is used to

prevent auto restart after loss of supply due to power failure.

auto restart the starter unit after loss of supply due to power failure.

prevent manually restart after loss of supply due to power failure.

auto stop the starter unit after loss of supply due to power failure.

4.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

A protection device which break a supply to the control circuit of the starter unit when there is a short circuit fault occur is

thermal overload relay.

molded case circuit breaker.

control fuse or miniature circuit breaker.

earth leakage circuit breaker.

5.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

    A red lamp is used to indicate       

a motor is in trip condition.

a motor is in stop condition.

A motor is in stop and trip condition.

a motor is in operation condition.

6.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

Media Image

Holding contact is provided by

limit switch normally close contact (LSc).

M contactor normally close auxiliary contact.

M contactor normally open auxiliary contact.

holding relay auxiliary normally open contact across the start button.

7.

MULTIPLE CHOICE QUESTION

1 min • 10 pts

Media Image

A delta connection is at the point

           

mark X.

mark W.

mark Z.

mark V.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?