Search Header Logo

EKG and Cardiovascular Testing

Authored by Miranda Mack-Delavallade

Science

University

Used 63+ times

EKG and Cardiovascular Testing
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant is preparing a patient who has shortness of breath for at EKG. In which of the following positions should be assistant place the patient?

Prone

Semi- Fowler's

Supine

Sims'

2.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant is preparing a patient for an EKG. Which of the following instructions should the medical assistant provide?

"Avoid food or drink for 4 hours prior to the test"

"Remove all clothing from the waist up"

"Apply moisturizing lotion to the electrode placement sites"

"Maintain a full bladder for the duration of the test"

3.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant is preparing to perform an EKG recording on a patient. Which of the following information is true of limb leads and electrodes?

Limb leads are unipolar

Leads V1 through V6 are limb leads

Limb leads are placed on the fleshly areas of the skin

The left leg wire serves as the ground

4.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant is calibrating an EKG machine. Which of the following should the assistant identify as the standard speed of the recording?

25 mm/second

50 mm/second

10 mm/second

5 mm/second

5.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant is preparing a patient for an EKG. In which of the following locations should the assistant place the V4 lead?

5th intercostal space at the anterior axillary line

5th intercostal space at the midaxillary line

Midway between V3 and V5

5th intercostal space at the midclavicular line

6.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant notes a wandering baseline throughout an EKG tracing. Which of the following electrocardiograph issues could have resulted in this occurrence?

The electrode pads were defective or poorly attached

The machine was missing the grounding prong for the outlet

The machine did not have the proper standardization settings set

The cable tips were loose or had become separated

7.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A medical assistant notices rhythmic sharp spikes throughout and EKG tracing. Which of the following artifacts is occurring?

wandering baseline

interrupted baseline

interference

somatic tremor

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?