1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

ASHRAE Standard 15-2013 requires the use of room sensors and alarms to detect?

A1 refrigerants

B2 refrigerants

A2 refrigerant

all refrigerant safety groups

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements is true of recycling and recovery equipment?

it must be tested by an AHRI-approved third party

it must be equipped with low loss ball valves and flare fittings

it must be able to handle more than one refrigerant

it must be labeled as certified to meet EPA's requirements.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following methods can be used to pressurize an R-1233zd system for the purpose of opening the system for a non-major repair?

adding nitrogen to the system

warming the liquid refrigerant in the system

adding compressed air to the system's condenser

adding carbon dioxide to the system's condenser and evaporator

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When should an appliance NOT be evacuated all the way to the prescribed level?

when performing a major repair followed by a minor repair

when the repair is followed by an evacuation of the appliance to the environment

when leaks in the appliance make evacuation to the prescribed level unattainable

when the appliance is being disposed of

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must be done after recovering the liquid refrigerant from a low-pressure chiller?

recover the vapor refrigerant

pressurize the system with nitrogen

separate the oil from the system

solvent flush the entire system

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should you do after reaching the required recovery vacuum on a low-pressure appliance?

immediately disconnect the recycling or recovery equipment and open the system for service

wait for at least a few minutes to see if the system pressure rises before charging

break the vacuum with nitrogen and open the system for service to begin charging liquid

pressurize the system with nitrogen and perform a leak check

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

R-123 at 14.7 PSIA will boil at approximately?

90°F

82°F

78°F

74°F

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?