1.

OPEN ENDED QUESTION

30 sec • 1 pt

When charging a refrigeration system with a near-azeotropic mixture, what must be done to prevent liquid from entering the system?

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is: Charge as a liquid through the low side using a restrictor.

2.

OPEN ENDED QUESTION

30 sec • 1 pt

The factory charge in a split system, using R-22, shows 6 lb. 8 oz. in the outdoor condensing unit and 2 oz. in the evaporator. The 3/8" liquid line contains 0.48 oz. per foot and the 7/8" suction line contains 0.10 oz. per foot. The refrigerant lines are 30' long. What is the correct refrigerant charge for this system?

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is: 7 lb. 11 oz.

3.

OPEN ENDED QUESTION

30 sec • 1 pt

If the tank is a reusable tank, there are no check valves and system refrigerant can enter the tank as long as the system pressure is higher than the pressure in the tank.

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is 'True'.

4.

OPEN ENDED QUESTION

30 sec • 1 pt

Refrigerant in vapor form is normally put into the system through the ____.

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is: suction line

5.

OPEN ENDED QUESTION

30 sec • 1 pt

Refrigerant in liquid form is normally put into the system through the ____.

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is: liquid line

6.

OPEN ENDED QUESTION

30 sec • 1 pt

When charging a system with vapor refrigerant from a refrigerant cylinder the cylinder will become ____.

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is: cold

7.

OPEN ENDED QUESTION

30 sec • 1 pt

One good feature of an electronic charging scale is that it counts upward as refrigerant is removed, to tell the technician how much refrigerant was used.

Evaluate responses using AI:

OFF

Answer explanation

The correct answer is 'True'.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?