EPA Type III Certification Test #1

EPA Type III Certification Test #1

University

20 Qs

quiz-placeholder

Similar activities

CHAPTER 43 EOC QUIZ

CHAPTER 43 EOC QUIZ

University

20 Qs

Assessment in Learning 1

Assessment in Learning 1

University

15 Qs

Etech

Etech

University

15 Qs

EPA 608 Exam Study Type III

EPA 608 Exam Study Type III

11th Grade - University

25 Qs

16. ACR-104 UNIT24 END OF UNIT

16. ACR-104 UNIT24 END OF UNIT

University

24 Qs

Dash warning symbols

Dash warning symbols

University

16 Qs

Hydraulics Week 1

Hydraulics Week 1

University

17 Qs

LV13 Transmission diagnostics

LV13 Transmission diagnostics

University

20 Qs

EPA Type III Certification Test #1

EPA Type III Certification Test #1

Assessment

Quiz

Instructional Technology

University

Medium

Created by

Camden McConnell

Used 21+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A typical setting for the high-pressure cut-out control on a recovery unit used for evacuating refrigerant from a low-pressure chiller is

2 psig

5 psig

10 psig

15 psig

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A charged low pressure refrigeration system can be efficiently leak-checked by

adding compressed air since it will be removed from the system by the purging unit.

operating the purge system.

adding HCFC-22.

raising system pressure by heating with circulated hot water or heating blankets.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The existence of air in a low pressure system causes

low head pressure.

low suction pressure.

high head pressure.

high liquid level.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which safety precaution should be adhered to for low pressure systems?

Do not siphon refrigerant by mouth.

Avoid spilling liquid refrigerant on your skin.

Use gloves and safety goggles when working with liquid refrigerant.

All of the above.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Refrigerant-11 (R-11) at 14.7 psia, will boil at about

60.3 F

74.5 F

79.5 F

80.2 F

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When there is excessive moisture collecting in the purge unit of a low pressure refrigeration system, this indicates that

the system with contaminated refrigerant.

the condenser or chiller barrel tubes are leaking.

the purge unit is not operating properly.

the purge unit needs adjustment.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

ASHRAE Standard 15-1994 requires equipment room refrigerant sensors for what safety group classification?

A1

B2

A2

All refrigerant safety groups.