2018 IPC CH 6A Study Quiz

2018 IPC CH 6A Study Quiz

Professional Development

25 Qs

quiz-placeholder

Similar activities

Pastry Ingredients and Functions

Pastry Ingredients and Functions

Professional Development

20 Qs

Riddles

Riddles

KG - Professional Development

20 Qs

Evidence (Chernoff) Class 1-4

Evidence (Chernoff) Class 1-4

University - Professional Development

20 Qs

HPDC Internal Training 032022

HPDC Internal Training 032022

Professional Development

20 Qs

R & I / Repair Track Adjuster & HIC Accumulator PC2000

R & I / Repair Track Adjuster & HIC Accumulator PC2000

Professional Development

20 Qs

GSC Quiz Bee

GSC Quiz Bee

Professional Development

20 Qs

WORKSHOP SCRUB NURSING

WORKSHOP SCRUB NURSING

Professional Development

20 Qs

Induction Assessment

Induction Assessment

Professional Development

20 Qs

2018 IPC CH 6A Study Quiz

2018 IPC CH 6A Study Quiz

Assessment

Quiz

Other

Professional Development

Medium

Created by

Johnny Thulin

Used 8+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A...is not permitted as a source for an individual water supply unless the water is treated to prevent contamination.

Spring
Cistern
Dug well
Drilled well
602.3.1

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The maximum allowable water pressure on the water distribution system is...

25 PSI

40PSI

80 PSI

100PSI

604.8

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

When the maximum allowable water pressure within a building is exceeded, a...is required.

flow control valve vented
pressure reducing valve
In-line pressure balancing valve
Pressure relief valve
604.8

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Where quick-closing valves are utilized in a water distribution system, a...shall be installed.

pressure reducing valve
flow control device
water hammer arrester
Pressure relief valve
604.9

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Joints between polyethylene of raised temperature (PE-RT) plastic tubing and fittings shall be joints…

heat fusion
mechanical
Solvent cemented
Threaded
604.24.1

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The maximum allowable lead content of water supply pipe and fittings supplying water for cooking or drinking is...percent.

0.02
8
2
0.25
605.2.1

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Which of the following is required to be installed with a pressure reducing valve?

strainer
ball valve
Check valve
Vacuum breaker
604.8

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?