2018 IPC CH 7A Study Quiz

2018 IPC CH 7A Study Quiz

Professional Development

25 Qs

quiz-placeholder

Similar activities

Quiz - Regulamentação do Aeronauta - Inicial Agente Suporte CCO

Quiz - Regulamentação do Aeronauta - Inicial Agente Suporte CCO

Professional Development

20 Qs

Module 233 Heat transfer pumps (NTT) test retake

Module 233 Heat transfer pumps (NTT) test retake

Professional Development

20 Qs

plumbing science 1

plumbing science 1

Professional Development

20 Qs

V27 SERIES REFRESHMENT

V27 SERIES REFRESHMENT

Professional Development

20 Qs

प्रश्नोत्तरी प्रतियोगिता (29.09.2023) - जालंधर क्षेत्र

प्रश्नोत्तरी प्रतियोगिता (29.09.2023) - जालंधर क्षेत्र

Professional Development

20 Qs

HAVAL H6 HEV-001-3

HAVAL H6 HEV-001-3

Professional Development

20 Qs

V29E PRE-ASSESSMENT

V29E PRE-ASSESSMENT

Professional Development

20 Qs

Oppo Practice Paper

Oppo Practice Paper

Professional Development

20 Qs

2018 IPC CH 7A Study Quiz

2018 IPC CH 7A Study Quiz

Assessment

Quiz

Other

Professional Development

Practice Problem

Medium

Created by

Johnny Thulin

Used 14+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

01. When is a common building sewer connecting more than one building to the public sewer allowed?

when the building tenants agree to the shared use of the sewer
when the city sewer system does not extend to the property line
when the common sewer is controlled by a property owners association
when all buildings using the common sewer are located on the same property
Sec. 701.3

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

02. Where the wastewater temperature will exceed __________ °F, the drainage piping material must be rated for the highest temperature of the wastewater.

110.0
120.0
140.0
160.0
Sec. 702.5

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

03. A solvent-cement joint between ABS and PVC plastic piping is __________.

prohibited
permitted in above ground locations only
permitted with yellow primer complying with ASTM D3138
permitted only where the building drain connects to the building sewer
Sec. 705.16.4

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

04. All of the following materials are approved for both above ground and below ground installations of the building drainage system except __________.

polyolefin
polyethylene
polyvinyl chloride
stainless steel
Tables 702.1 and 702.2

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

05. A chemical waste piping system requires __________.

dilution of the chemicals involved
resistance to the undiluted chemicals involved
complete separation from the sanitary drainage system
schedule 80 weight pipe or equivalent
Sec. 702.6

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

06. Mechanical and ________ joints are approved for polyethylene plastic pipe installed underground.

threaded
caulked
solvent-cemented
heat-fusion
Sec. 705.12.1

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

07. The make-up of a solvent cement joint in 6-inch PVC DWV piping requires application of __________.

purple primer
combination primer/solvent cement conforming to ASTM F493
purple primer or solvent cement that is yellow in color
purple primer or solvent cement that is purple in color
Sec. 705.10.2

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?