Domestic Cold Water 6035-02 | Part 2

Domestic Cold Water 6035-02 | Part 2

Professional Development

40 Qs

quiz-placeholder

Similar activities

Personality_MBTI

Personality_MBTI

University - Professional Development

40 Qs

Indefinite Pronouns

Indefinite Pronouns

Professional Development

40 Qs

Earth Day Vocabulary

Earth Day Vocabulary

KG - Professional Development

43 Qs

THEORY OF DEMAND

THEORY OF DEMAND

Professional Development

45 Qs

Characters in the Bible

Characters in the Bible

3rd Grade - Professional Development

45 Qs

Level 2 Plumbing - Hot Water

Level 2 Plumbing - Hot Water

12th Grade - Professional Development

43 Qs

GLOW Basic Digital Freelance Module Assessment Test 2022

GLOW Basic Digital Freelance Module Assessment Test 2022

Professional Development

40 Qs

MGNF Quiz - 61

MGNF Quiz - 61

Professional Development

40 Qs

Domestic Cold Water 6035-02 | Part 2

Domestic Cold Water 6035-02 | Part 2

Assessment

Quiz

Other

Professional Development

Medium

Created by

George Harding

Used 181+ times

FREE Resource

40 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What component must be sited immediately after the supply stop valve on entry to a property?

Single check valve

Ferrule valve

Drain off valve

Service valve

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of valve should be installed in order to isolate the CWSC?

Service valve

Float operated valve

Gate valve

Stop valve

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the service pipe is located within 750mm of the outside wall, what action should be taken?

Contact the Water Undertaker

Reposition pipework further than 750mm

Reposition the wall so the pipework is further than 750mm

Insulate the pipework

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Limescale is created by what mineral being in temporary hard water?

Calcium carbonate

Sodium

Soft water

Calcium sulphate

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What pipes is the Water Undertaker responsible for maintaining?

Communication pipes

Service pipes

Both pipes

None of the pipes

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT known as a "Underground sources" of water?

Wells

Borehole

Springs

Streams

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What item should be used to test the PPM in water?

Weir cup

Pressure gauge

Flow cup

Hardness test kit

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?