NPCP SPECIAL

NPCP SPECIAL

2nd Grade

33 Qs

quiz-placeholder

Similar activities

CMFCIQUIZ1

CMFCIQUIZ1

KG - Professional Development

30 Qs

Part book Reading BMC

Part book Reading BMC

1st Grade - Professional Development

35 Qs

Les CONDUITS

Les CONDUITS

1st - 3rd Grade

28 Qs

ENGINE XI TAB

ENGINE XI TAB

2nd Grade

30 Qs

Plumbing Quiz 1

Plumbing Quiz 1

KG - Professional Development

30 Qs

NPCP 2 defination 6

NPCP 2 defination 6

2nd Grade

32 Qs

Building Laws Quiz 7- RA9514

Building Laws Quiz 7- RA9514

KG - Professional Development

30 Qs

NPCP 2 defination 7

NPCP 2 defination 7

2nd Grade

38 Qs

NPCP SPECIAL

NPCP SPECIAL

Assessment

Quiz

Professional Development

2nd Grade

Easy

Created by

dream mayang

Used 9+ times

FREE Resource

33 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

a Registered and Licen§e(i Master Plumber. without limitations. pursuant to Republi~ Act 1378, as amended. and shall be submitted in _____ of the aforementioned requirements with each application for a permit.

six (6) sets

four (4) sets

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

All Administrative Plumbing Personnel, Plumming Inspector shall be a Registered and Licensed Master Plumber in accordance with the provision of

_______, otherwise, known as "Plumbing Law··.

Republic Act 1378

Republic Act 1978

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Exception:

Where one building stand in the rear of another building on an interior lot, and no private sewer line is available nor can be constructed to the rear building through an adjoining court, yard or driveway, the building drain from the front building may be extended to the rear building if the existing size is adequate for both buildings and gravity flow is____

possible

impossible

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

• Lead and copper sub-pans or linings shall be installed from all conducting substances other than their connecting drain by 6.8 kg asphalt felt or its equivalent and no lead pan or liner shall be constructed of material weighing less than 19.6 kglm 2 . Thickness of copper pans or liners shall be at least ______ thick. Joint in lead pans or liners shall he burned. Joints in copper pans or liners shall be soldered or brazed.

Gauge No. 24 B & S (0.5 mm)

Gauge No. 22 B & S (0.4 mm)

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Exception:

Where a grounding system acceptable to the Administrative Authority is installed, inspected, and approved. metallic pipe may be replaced with ____

non-metallic pipe.

Copper pipe.

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Note:

For the purpose of this section, "within the building" shall mean ____

within the fixed limits of the building foundation.

within the perimeter center of the building foundation.

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

No building water service pipe shall be less than ____ in diameter.

19 mm

12 mm

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?