Chapter 08 2021 UPC

Chapter 08 2021 UPC

30 Qs

quiz-placeholder

Similar activities

Set 01 - Plumbing Code - Basic Questionnaire by ARC

Set 01 - Plumbing Code - Basic Questionnaire by ARC

KG - University

31 Qs

Keystone biology Module A

Keystone biology Module A

KG - University

30 Qs

Independent Living

Independent Living

9th - 12th Grade

27 Qs

FUTURE FORMS (fill in the blank)

FUTURE FORMS (fill in the blank)

KG - University

25 Qs

Word Trek Lesson 5

Word Trek Lesson 5

KG - University

25 Qs

Verb Test

Verb Test

6th - 8th Grade

35 Qs

SOAL SUMATIF PH ( IPAS) KELAS IV SDN BANJARARUM II ( Olimpiade )

SOAL SUMATIF PH ( IPAS) KELAS IV SDN BANJARARUM II ( Olimpiade )

KG - University

25 Qs

Chapter 08 2021 UPC

Chapter 08 2021 UPC

Assessment

Quiz

others

Medium

Created by

Jeremy Sandor

Used 32+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. All indirect waste piping that requires an air gap shall discharge into the building drainage system through ____________________________.
a. an automatic vent
b. an air gap of two pipe diameters
c. drainage air gap of 1 inch minimum
d. a trap

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

2. Except for refrigeration coils and ice-making machines, the minimum size of the indirect waste pipe shall not be smaller than the drain on the unit and not smaller than ___ inch(es).
a. 3/4
b. 1
c. 1-1/4
d. 1-1/2

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

3. Floor drains in walk-in coolers shall discharge ____________.
a. directly to the main building drain
b. directly to the exterior of the building
c. to a separate drainage line discharging into an outside receptor through an air gap or airbrake
d. to a grease interceptor

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

4. The developed length from the fixture outlet of a bar sink to the receptor shall not exceed ____ feet.
a. 6
b. 5
c. 3
d. 15

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

5. If the trap from a sink located in a bar cannot be vented, ____________________________.
a. the drain shall discharge through an air gap or air break into an approved receptor that is vented
b. the fixture must be relocated
c. the discharge may be pumped to an approved receptor
d. a drum trap shall be used

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

6. Drains, overflows, or relief pipes from a water distribution system shall discharge to the building drain by _____.
a. indirect waste by means of a water-distribution airgap
b. direct connection to the building drain
c. direct connection to the building drain through a trap
d. indirect waste piping through a vented trap

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

7. Stills, sterilizers, and similar equipment that produce waste shall be ____________________________.
a. connected directly to the building drain
b. directly connected to the building drain using an air break
c. indirectly connected by means of an air gap
d. indirectly connected to a lavatory tailpiece