Chapter 15 2021 UPC

Chapter 15 2021 UPC

28 Qs

quiz-placeholder

Similar activities

Tricky Quizzes

Tricky Quizzes

6th Grade

26 Qs

Evaluacion Word

Evaluacion Word

KG - University

26 Qs

 Paper 1: The Physical Environment Revision Quiz

Paper 1: The Physical Environment Revision Quiz

KG - University

28 Qs

Fermentable carbs exercise

Fermentable carbs exercise

KG - University

25 Qs

5th Grade: Shurley English Chapter 11

5th Grade: Shurley English Chapter 11

KG - University

25 Qs

Chapter 15 2021 UPC

Chapter 15 2021 UPC

Assessment

Quiz

others

Practice Problem

Medium

Created by

Jeremy Sandor

Used 76+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

28 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. The provisions of______________shall apply to the construction, alteration, and repair of alternate water source systems for non potable applications.

a. this chapter
b. the authority having jurisdiction
c. this chapter and the Washington State Department of health
d. the Washington State Department of health

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

2. Gray water installations having a minimum discharge capacity of ______ gallons per day shall be designed by a registered design professional.

a. 150
b. 175
c. 200
d. 250

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

3. Each room containing on-site treated water equipment shall have a sign posted with _____ inch letters.

a. 1/4”
b. 1/2”
c. 3/4”
d. 1”

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

4. Cross-connection inspection and testing on both potable and reclaimed water systems shall be performed ____.

a. initially
b. annually
c. semi-annually
d. initially and annually

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

5. Upon discovery of a cross connection, the potable water system shall be chlorinated with ____ parts per million.

a. 50
b. 75
c. 100
d. 110

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

6. Reclaimed water pipes shall be permitted to be run in the same trench as potable water pipes with a _____ inch minimum vertical and horizontal separation where both pipe materials are approved for use within a building.

a. 6
b. 12
c. 18
d. 24

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

7. On-site treated non potable water piping sizing shall comply with ______.

a. table 610.3
b. table 702.1
c. chapter 6
d. chapter 7

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?