Heat Pump Test ( Week 3)

Heat Pump Test ( Week 3)

University

12 Qs

quiz-placeholder

Similar activities

HVAC/R - (Heating. Ventilation and Refrigeration)

HVAC/R - (Heating. Ventilation and Refrigeration)

11th Grade - University

10 Qs

Electrical Induction

Electrical Induction

8th Grade - University

15 Qs

Pollutants

Pollutants

12th Grade - University

15 Qs

Heat pump Test 1 (Week 1)

Heat pump Test 1 (Week 1)

University

16 Qs

PRESS MOULDING DTP

PRESS MOULDING DTP

University

10 Qs

DC Motor Questions

DC Motor Questions

University

10 Qs

Forces at a Distance

Forces at a Distance

8th Grade - University

15 Qs

FKAB@UKM

FKAB@UKM

University

9 Qs

Heat Pump Test ( Week 3)

Heat Pump Test ( Week 3)

Assessment

Quiz

Science

University

Medium

NGSS
MS-PS3-3, MS-PS1-4, MS-PS3-4

Standards-aligned

Created by

Neymar boy

Used 12+ times

FREE Resource

12 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

The temperature split across an indoor coil is normaly equal to a range of 17° to 21°.

True

False

Tags

NGSS.MS-PS1-4

NGSS.MS-PS3-4

2.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Nomenclature for the heat pump is different than a straight air conditioning system.  The small copper line connecting the indoor and outdoor coils is known as the _______________.

gas

hot vapor

suction

liquid

3.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

Typically, the minimum air flow for heat pump applications is __________________.

400 fpm/ton

400 cfm/ton

350 fpm/tom

450 cfm/ton

Tags

NGSS.MS-PS1-4

NGSS.MS-PS3-3

NGSS.MS-PS3-4

4.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

In the cooling mode, the refrigerant in the gas line is at a __(1)__ temperature and flowing __(2)__ the indoor coil.

1) - low

(2) - away from

(1) - high

(2) - towards

(1) - high

(2) - away from

(1) - low

(2) - towards

Tags

NGSS.MS-PS1-4

NGSS.MS-PS3-3

5.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

The vapor line (gas line) of a heat pump system is sized to provide a minimum velocity of __________ in a horizontal run.

700 cfm

1500 fpm

700 fpm

1500 cfm

6.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

In the heating mode, which way is the liquid refrigerant inside the liquid line flowing?

from the compressor to the indoor coil

from the indoor coil to the outdoor coil

from the compressor to the outdoor coil

from the outdoor coil to the indoor coil

Tags

NGSS.MS-PS3-3

7.

MULTIPLE CHOICE QUESTION

5 mins • 1 pt

One of the reasons that the heat pump is so efficient is because it can achieve supply air temperatures similar to that of fossil-fuel (gas/oil) systems, usually around 140°F.

True

False

Tags

NGSS.MS-PS3-3

NGSS.MS-PS3-4

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?