Extinguishing agents and Systems

Extinguishing agents and Systems

Professional Development

10 Qs

quiz-placeholder

Similar activities

rappers

rappers

5th Grade - Professional Development

10 Qs

Đặc điểm, ứng dụng gạc Hydrocolloid

Đặc điểm, ứng dụng gạc Hydrocolloid

Professional Development

10 Qs

Slime

Slime

KG - Professional Development

6 Qs

201 (4)

201 (4)

KG - Professional Development

15 Qs

Fire Emergency Procedure

Fire Emergency Procedure

Professional Development

10 Qs

9-Speed Auto Trans Diag and repair (LV2)

9-Speed Auto Trans Diag and repair (LV2)

Professional Development

12 Qs

Fire Emergency Procedure

Fire Emergency Procedure

Professional Development

10 Qs

Name the rapper

Name the rapper

KG - Professional Development

15 Qs

Extinguishing agents and Systems

Extinguishing agents and Systems

Assessment

Quiz

Other

Professional Development

Medium

Created by

Hussain Shifau

Used 4+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

The most common extinguishing agents used in ARFF vehicles are:

Water, Foam & Dry Chemical

Water, CO2 & Foam

Water, Foam & Nitrogen

Water, AFFF & Dry Chemical

2.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

There are different types of _______ and _______foam proportioning devices commonly found in portable and apparatus-mounted applications.

Large & Small

High energy & Low energy

High pressure & Low pressure

High temperature and Low temperature

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

which of the following is a method of foam proportioning?

Conduction

Induction

Convection

Radiation

4.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

A Disadvantage of batch mixing is....?

All water onboard the apparatus is converted to foam

Need a separate foam pump with power take-off(PTO) or other power source

No recirculation back to foam concentrate tank

Foam concentrate flow and pressure match system demand

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Examples of induction devices are....?

In-line eductors and foam-nozzle eductors

Skid-mounted multiagent units and wheeled extinguishers

Roof turret and bumper turret

Pre-connected hoseline and Controlled branch

6.

MULTIPLE CHOICE QUESTION

45 sec • 1 pt

What is the disadvantage of around the pump proportioning system?

Need for a separate foam pump with power take-off (PTO) or other power source

The foam injection point must be within the piping before any manifolds or distribution to multiple fire pump discharges.

Pump must be dedicated solely to foam operation. It does not allow plain water and foam to be discharged from the pump at the same time

Maintained in a ready-to-pump condition and requires no flushing after use

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

From the following what is an apparatus mounted foam proportioning system?

Around the pump proportioners

Foam nozzle eductors

Skid-mounted multiagent units

Roof and bumper turret

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?