IMC Random 2

IMC Random 2

Professional Development

30 Qs

quiz-placeholder

Similar activities

Permit to work and Lock out tag out Question banks

Permit to work and Lock out tag out Question banks

Professional Development

28 Qs

Coal & Coal Dust

Coal & Coal Dust

Professional Development

29 Qs

Childcare Development Ch. 3 Learning Environment

Childcare Development Ch. 3 Learning Environment

Professional Development

25 Qs

Contract Management a continual  procurement process

Contract Management a continual procurement process

Professional Development

25 Qs

MET Session 6 Quiz

MET Session 6 Quiz

Professional Development

30 Qs

School-Based Management

School-Based Management

Professional Development

25 Qs

Session 2022-12

Session 2022-12

Professional Development

27 Qs

PRE-TEST

PRE-TEST

Professional Development

25 Qs

IMC Random 2

IMC Random 2

Assessment

Quiz

Professional Development

Professional Development

Hard

Created by

Johnny Thulin

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Except where a reduction is permitted by Section 308, a non-listed chimney connector serving a medium-heat appliance must be provided with a min. clear. of _ “ to combustibles.
9
18
24
36
803.10.6 Table

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

A door and passageway measuring _ “ in width and 80 “ in height shall provide access to an appliance located in a room.
22
24
32
36
306.2

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Used mtrl.s, equip. and appliances may be utilized under which of the following conditions?
Elements have been reconditioned, placed in proper working order and
They are limited to 10 percent of the total materials.
Used materials may never be utilized in new construction.
A representative sampling is tested for compliance.
105.5

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Suspended Mech. equip. shall be installed a min. of _ “ above grade.
3
4
5
6
304.1

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

When a bldg. permit is issued, the constr. documents shall be stamped _.
“Approved for Construction”
“Approved”
“Accepted as Reviewed”
“Reviewed for Code Compliance”
106.4.1

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Attics with equip. shall have an unobstructed passageway at least _ “ wide.
22
24
28
30
306.3

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Outdoor air intake openings shall be permitted to be located less than 10’ horiz. from a street, alley, parking lot or loading dock, provided the openings are located not less than _ ‘vert. above such locations.
3
10
15
25
401.4, #2

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?