HVAC Heat Pump Test 2 (Week 6)

Authored by Neymar boy

Science

University

NGSS covered

Used 17+ times

HVAC Heat Pump Test 2 (Week 6)
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

When Auxiliary Heat is used by itself or in the case of Heat Pump Failure, it is known as:

Additional Heat

Supplemental Heat

Accessory Heat

Emergency Heat

2.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

Outdoor thermostats are used to stage the heat strips at different outdoor temperatures and are wired in series with the control voltage of the electric strips.

True

False

Tags

NGSS.MS-PS3-3

3.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

The control most often used to stage the electric heat strips is the:

Defrost Relay

Automatic Switch

Blower Motor Relay

Sequencer

4.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

When referring to a Heat Pump Thermostat, “Y” will energize:

Only when there is a call for the Indoor Blower in the Fan On position

Only when there is a call for cooling in the Cool Mode

When there is a call for cooling in the Cool Mode or when there is a call for heat in the Heat Mode

Only when there is a call for heat in the Heat Mode

Tags

NGSS.MS-PS3-3

NGSS.MS-PS3-4

5.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

When referring to a Heat Pump Thermostat, “O” will energize:

a. Reversing Valve in the Cooling Mode

b. Reversing Valve in the Heating Mode

c. Indoor Blower

d. Compressor Contactor

Tags

NGSS.MS-PS3-3

NGSS.MS-PS3-4

NGSS.MS-PS1-4

6.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

The thermostat should always be mounted at least 52" inces above the floor near the main return on an outside wall.

True

False

7.

MULTIPLE CHOICE QUESTION

3 mins • 1 pt

What safety control is designed to open or "break" the control voltage to the compressor contactor when there is a problem resulting in an extremely large rise in the refrigerant pressure.

Fusible Link

Thermal-Cutout

Loss of Charge Switch

High-Pressure Switch

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?