Refrigeration 2

Refrigeration 2

9th Grade

28 Qs

quiz-placeholder

Similar activities

3º ESO PLASTIC

3º ESO PLASTIC

1st - 12th Grade

26 Qs

Cooking Methods

Cooking Methods

9th - 12th Grade

29 Qs

AP Psych 7 Cognition

AP Psych 7 Cognition

9th - 12th Grade

23 Qs

Mktg-Distribution, Location, Transportation

Mktg-Distribution, Location, Transportation

9th - 12th Grade

27 Qs

Principles of Ag Tools

Principles of Ag Tools

9th - 12th Grade

27 Qs

Ecology: Nutrient Cycles

Ecology: Nutrient Cycles

7th - 12th Grade

23 Qs

Module 27: First Aid/CPR

Module 27: First Aid/CPR

9th - 12th Grade

25 Qs

EPA 608 - TYPE 1

EPA 608 - TYPE 1

9th - 12th Grade

27 Qs

Refrigeration 2

Refrigeration 2

Assessment

Quiz

Other

9th Grade

Medium

Created by

Charles Whittaker

Used 8+ times

FREE Resource

28 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When recovery of the refrigerant has been completed, how can the system be checked to see if there are pockets of cold liquid refrigerant?

If the pressure rises to 5 psi or more with the system shut off for five minutes.

If the pressure drops after the system is shut off for five minutes or more.

If the pressure rises to 10 psi or more with the system shut off for five minutes or more.

None of the answers

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the meaning of the term "reclaimed"?

To clean refrigerant for reuse.

To remove refrigerant an d store it in an external container without testing or processing.

To reprocess the refrigerant.

None of these choices.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Purging is a term which describes _____.

leakage of refrigerant into the atmosphere.

removing unwanted air, vapors, dirt or moisture from a system.

removing excess dirt from the atmosphere.

adding refrigerant to a system.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a very important precaution one must take when filling refrigerant cylinders?

Boey refirgerant color code.

Never fill cylinders over 80% of capacity.

Both A and B

Never reuse refrigerant cylinders.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the meaning of the term "recycled"?

To clean for reuse.

To remove refrigerant and store it in an external container without testing or reprocessing.

To reprocess refrigerant.

None of these choices.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The primary method of removing refrigerant using recovery equipment is the _____ method.

liquid recovery

vapor recovery

either A or B is acceptable

method of recovery varies based upon the type of refrigerant used

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why is a purge cyle required on low pressure chillers?

Operating pressure may be below atmospheric pressure.

Because of the refrigerants low boiling point.

Non-condensables in the system.

Chiller may be opened for maintenance.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?