
Principal Structure 1st
Authored by Tawatchai ENDOO
Arts
University
Used 3+ times

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
11 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
20 sec • 1 pt
What's direction that the target's ship coming to our ship?
it's coming upon our head.
it gonna pass our port bow.
it's undesireable yet.
it passed through starboard bow then it is turning to our port bow.
2.
MULTIPLE CHOICE QUESTION
20 sec • 1 pt
How about the length of this ship approximately?
50 - 100 metres.
0 - 50 metres.
>=50 metres.
>50metres.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The vertical lines at the aft and fore by right angle with waterline are AP and FP, aren't it?
If yes, the rang between AP to FP is Length between perpendicular, isn't it?
No, it's the visualization line.
Yes, it is.
Not at all. The AP and FP are not concerned with LBP.
Yes, but LBP suppose to be concerned with AP, FP and Length Over all as well.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Where the proper base line is?
The parallel line with the centre line closely.
Beneath bottom shell plating.
The topmost of the keel, excluding the bottom shell plating.
The top of the keel, including the bottom shell plating.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
1: The Molded Beam, Molded Dept and Molded Draught are considered with base line, aren't it?
2: The measurement of those values are included with the thickness of steel plating, aren't it?
absolutly yes.
I think so.
it's probably.
Yes for the first questions, but the measurment is not consider with thickness of steel.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the Extreme dept,draught and beam?
The extreme is consider with the thickness of plating, so the extreme dept is the depth of from upper deck to lowest point of keel, extreme draught from the lowest point of keel to the summer load line and extreme beam is maximum beam taken over all extremities.
The extreme is not consider with the thickness of plating, so the extreme dept is the depth of from upper deck to lowest point of keel, extreme draught from the lowest point of keel to the summer load line and extreme beam is maximum beam taken over all extremities.
The extreme dept, draught and beam are using the rough weather especailly.
All of above are not correct.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
How measure the camber ?
Measurement at the both side of the ship to the top of curvation camber at the center ship.
Measurement at the both side of the ship through the stars on the sky.
Measurement at the both side of the ship to the topmost of the ship.
Curvation is absolute value, so just measure as a straight line.
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Microsoft
or continue with
%20(1).png)
Apple
Others
Already have an account?