Spray applied fireproofing 1a

Spray applied fireproofing 1a

1st - 5th Grade

11 Qs

quiz-placeholder

Similar activities

Feature or Trait?

Feature or Trait?

5th - 8th Grade

15 Qs

SITB lessons 28-30

SITB lessons 28-30

1st - 5th Grade

10 Qs

Nature of Science Vocabulary 2021

Nature of Science Vocabulary 2021

4th - 5th Grade

14 Qs

Measurement

Measurement

5th Grade

14 Qs

Measurement and Motion

Measurement and Motion

5th - 6th Grade

10 Qs

Earth's Layer

Earth's Layer

3rd - 8th Grade

11 Qs

Physical Quantities and Measurements - Part 1 (Area)

Physical Quantities and Measurements - Part 1 (Area)

1st - 5th Grade

12 Qs

Spray applied fireproofing 1a

Spray applied fireproofing 1a

Assessment

Quiz

Science

1st - 5th Grade

Easy

Created by

Piledriverob Piledriverob2375

Used 12+ times

FREE Resource

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to the IBC, for SFRM not more than ___ of the individual thickness measurements shall be less than that specified in the construction documents

10 %

20 %

25%

Answer explanation

IBC 1705.15.4

THICKNESS:

Not more than 10% of the thickness measurements of the sprayed fire-resistant material applied to FLOOR, ROOF and WALL assemblies & structural members shall be less than the thickness required by the approved fire-resistance design,

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

___% of primary structural frame members shall be measured for thickness determination

25%

10%

20%

Answer explanation

IBC 1705.15.4.5

STRUCTURAL MEMBERS:

............Thickness testing shall be performed on not less than 25 percent of the structural member on each floor

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When verifying thickness of SFRM for FLOOR, ROOOF and WALL assemblies, at least ____ measurements shall be made for every _____ of sprayed area or portion thereof in each story

FOUR /

1000ftsq

8 /

2500

9 /

2500

Answer explanation

IBC

1705.15.4.2

FLOORS, ROOF, and WALL assemblies:

..........not less than FOUR measurements for each 1,000 square feet of the sprayed area

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many measurements at a single cross section are required for a wide flange column

12

seven

one

Answer explanation

IBC

1705.15.4.8

WIDE FLANGED COLUMN:

at wide flanged columns, thickness measurements shall be made AT 12 LOCATIONS........

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum allowable individual thickness measurements if the specified thickness is 1-5/8 inches ?

1 - 3/8 in.

one and five eighth

one and seven sixteenth

Answer explanation

IBC

1705.15.4.1

MINIMUM ALLOWABLE THICKNESS:

for design thicknesses 1 inch or greater the minimum allowable individual thickness shall be the design thickness minus 1/4 inch.......................

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to the building code how often should DENSITY samples for a FLOOR assembly be taken ?

EVERY 2500 square feet

1000 ft/sq

12 ft

Answer explanation

IBC

1705.15.5

DENSITY:

......................

  1. 1. From each FLOOR , ROOF and WALLS assembly at the rate of not less than ONE sample for every 2,500 square feet of portion thereof of the sprayed area in each story.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many measurements at a single cross section are required for a beam

9

seven

twelve

Answer explanation

IBC

1705.15.4.6

BEAMS and GIRDERS:

At BEAMS & GIRDERS thickness measurements shall be made at NINE locations around the BEAM or GIRDER at each end of a 12 inch length

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?