Prestressed Concrete HW 1a

Prestressed Concrete HW 1a

Professional Development

11 Qs

quiz-placeholder

Similar activities

Latihan AIP Lapangan Terbang Langkawi

Latihan AIP Lapangan Terbang Langkawi

Professional Development

11 Qs

Appetisers and salads lesson 2

Appetisers and salads lesson 2

Professional Development

12 Qs

Les effets de la manutention

Les effets de la manutention

Professional Development

14 Qs

Le groupe de sécurité

Le groupe de sécurité

Professional Development

10 Qs

DT Modul 4

DT Modul 4

Professional Development

10 Qs

Kuiz week 13 DTA1204

Kuiz week 13 DTA1204

Professional Development

10 Qs

Navy Enlisted Ranks

Navy Enlisted Ranks

KG - Professional Development

10 Qs

Officer Rank Insignia

Officer Rank Insignia

KG - Professional Development

10 Qs

Prestressed Concrete HW 1a

Prestressed Concrete HW 1a

Assessment

Quiz

Professional Development

Professional Development

Easy

Created by

Piledriverob Piledriverob2375

Used 29+ times

FREE Resource

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What document shows specific details including number , size, length, marking, elongation, profile, support system & location of all Tendons?

PT installation Drawings

rfi's

shop drawings

Answer explanation

FIELD MANUAL 2.2

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum size and quantity of Hairpin bars required for group of banded Anchors ?

#3 Hairpins Equal to # of a

Anchors +1

#4 hairpins 6

#5 hairpins

Answer explanation

FIELD MANUAL fig. 4-3a

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How far should back up bars extend past the last Anchor device ?

12 INCHES

12 plus 1

6 inches

Answer explanation

FIELD MANUAL fig. 4-3a

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a banded system, what is the maximum number of Tendons recommended to be bundled in a group ?

5

six

twelve

Answer explanation

FIELD MANUAL 4.4.15

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a banded system, what is the maximum number of Tendons recommended to be bundled in a group ?

5

six

twelve

Answer explanation

FIELD MANUAL 4.4.15

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum required size & quantity of a back up bars ?

TWO #4 BARS

1 bar 12"

4 bars

Answer explanation

FIELD MANUAL FIG. 4-3a

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How much Tendon tail should be outside the edge form for a stressing location ?

12 inches

thirteen inches

six inches

Answer explanation

FIELD MANUAL 4.4.12

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?