MEDICAL LABORATORY TECHNICAL COURSE HOSPITAL BENTONG 2023

MEDICAL LABORATORY TECHNICAL COURSE HOSPITAL BENTONG 2023

Professional Development

36 Qs

quiz-placeholder

Similar activities

Python Basics 2

Python Basics 2

5th Grade - Professional Development

36 Qs

US National Parks

US National Parks

Professional Development

34 Qs

Hema 2 Lab - Finals Exam

Hema 2 Lab - Finals Exam

Professional Development

40 Qs

EMT Trauma Unit Vocab

EMT Trauma Unit Vocab

11th Grade - Professional Development

36 Qs

How you understand HD?

How you understand HD?

University - Professional Development

32 Qs

Med Chem: Toxicology Part II

Med Chem: Toxicology Part II

Professional Development

31 Qs

GNSS Ground Course

GNSS Ground Course

Professional Development

32 Qs

Philippine Electrical Code (PEC-1A)

Philippine Electrical Code (PEC-1A)

Professional Development

35 Qs

MEDICAL LABORATORY TECHNICAL COURSE HOSPITAL BENTONG 2023

MEDICAL LABORATORY TECHNICAL COURSE HOSPITAL BENTONG 2023

Assessment

Quiz

Science

Professional Development

Medium

Created by

nora nora

Used 2+ times

FREE Resource

36 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The following are desired criteria for IQC material EXCEPT:

Levels of IQC should span the clinically relevant concentrations of the analyte.

Convenient size of aliquots/vials can be prepared.

   IQC material should NOT mimic the composition of patient samples.

Ready to use and require minimum preparation

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The following are true regarding assigning an IQC range EXCEPT:

Initially, a minimum of 20 data points, ideally from 20 separate days should be used.

Values should be reviewed once data from longer-term stable operation has been obtained

The acceptable range of IQC values (2SD/3SD, etc) should be determined based on the required quality of the assay

Failed IQC values should be excluded from the cumulative data.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

  The following are examples of RANDOM error EXCEPT:

      Pipetting error

Reagent lot bias

Electrical interference

Detector variation

4.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

The 2015 Milan Mandated Quality Hierarchy includes which of the following:

Goals based on analytical performance related to clinical outcomes

  Goals based on biological variation

     Expert group opinions

   EQA/PT goals

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

      What is the formula for calculating sigma metric?

  (TEa/Bias) – CV

(TEa – CV) / Bias

    TEa / (Bias –CV)

   (TEa – Bias) / CV

6.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

    The sigma metric can be used to:

  Identify assays that require improvement (and those that do not)

Define the required quality of an assay

  Determine the optimal IQC rules for an assay

Provide guidance on the frequency of IQC required

7.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

     The appropriate reaction to an IQC rejection should be to:

stop analysis & troubleshoot the problem

   correct the error

document the error that occurred and the corrective actions taken

document the error that occurred and the corrective actions taken

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?