What is the purpose of fault calculation in a power system?

Fault Analysis

Quiz
•
Physics
•
University
•
Hard
Deepti Randive
FREE Resource
10 questions
Show all answers
1.
MULTIPLE SELECT QUESTION
30 sec • 1 pt
To estimate the current flowing immediately after a fault occurs
To determine the settings of the relays that control the circuit breakers
To analyze the types of faults that can occur in a power system
To calculate the impedance of transformers during a fault
2.
MULTIPLE SELECT QUESTION
30 sec • 1 pt
What are the types of faults that can occur in a power system?
Shunt faults and series faults
Symmetrical faults and unsymmetrical faults
Positive sequence faults and negative sequence faults
Zero sequence faults and double line to ground faults
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What are the sequence components of a three-phase system?
Positive sequence components, negative sequence components, and zero sequence components
Symmetrical components, asymmetrical components, and balanced components
Primary components, secondary components, and tertiary components
Real components, reactive components, and apparent components
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of sequence networks in fault analysis?
To calculate the fault current during a symmetrical fault
To determine the impedance of transformers during a fault
To analyze the types of faults that can occur in a power system
To resolve unbalanced system vectors into balanced system vectors
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the difference between a symmetrical fault and an unsymmetrical fault?
A symmetrical fault has equal fault currents in the lines with 120 degrees phase displacement, while an unsymmetrical fault has unequal fault currents with unequal phase displacement
A symmetrical fault occurs during a short circuit, while an unsymmetrical fault occurs during an open circuit
A symmetrical fault occurs in the transmission lines, while an unsymmetrical fault occurs in the distribution lines
A symmetrical fault can be resolved into positive, negative, and zero sequence components, while an unsymmetrical fault cannot
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the equivalent circuit of a generator during a line-to-ground fault?
Open circuit
Short circuit
Series circuit
Parallel circuit
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the short circuit MVA of four generators connected in parallel with a rating of 100 MVA each and a sequence impedance of 0.12 pu?
3333.33 MVA
400 MVA
250 MVA
5000 MVA
Create a free account and access millions of resources
Similar Resources on Wayground
10 questions
Natural disasters

Quiz
•
University
8 questions
8 Capacitance

Quiz
•
12th Grade - University
10 questions
Curvilinear Motion of Particles - Review

Quiz
•
University
14 questions
Physics concepts Electricity 2

Quiz
•
8th Grade - University
10 questions
The Invention of Transistors and Integrated Circuits

Quiz
•
University
15 questions
Electrical Fault Diagnosis and Rectification

Quiz
•
University
5 questions
Fault Current

Quiz
•
University
10 questions
PROJECTILE MOTION

Quiz
•
9th Grade - University
Popular Resources on Wayground
25 questions
Equations of Circles

Quiz
•
10th - 11th Grade
30 questions
Week 5 Memory Builder 1 (Multiplication and Division Facts)

Quiz
•
9th Grade
33 questions
Unit 3 Summative - Summer School: Immune System

Quiz
•
10th Grade
10 questions
Writing and Identifying Ratios Practice

Quiz
•
5th - 6th Grade
36 questions
Prime and Composite Numbers

Quiz
•
5th Grade
14 questions
Exterior and Interior angles of Polygons

Quiz
•
8th Grade
37 questions
Camp Re-cap Week 1 (no regression)

Quiz
•
9th - 12th Grade
46 questions
Biology Semester 1 Review

Quiz
•
10th Grade