Central Heating Quiz phase 2 1.4/3

Central Heating Quiz phase 2 1.4/3

Professional Development

9 Qs

quiz-placeholder

Similar activities

PP 13 Central Heating System Quiz

PP 13 Central Heating System Quiz

Professional Development

10 Qs

pp1 central heating 1.4

pp1 central heating 1.4

Professional Development

10 Qs

pp5 Heating System Components Quiz

pp5 Heating System Components Quiz

Professional Development

11 Qs

PP 12 Central Heating Decommissioning Quiz

PP 12 Central Heating Decommissioning Quiz

Professional Development

6 Qs

Central Heating Systems QuizL3P2U7,1.12

Central Heating Systems QuizL3P2U7,1.12

Professional Development

10 Qs

Furnace Wiring

Furnace Wiring

Professional Development

10 Qs

ACS CCN1 Quiz 3

ACS CCN1 Quiz 3

Professional Development

11 Qs

Kick Off Meeting Bulan Energy & Loss 2022

Kick Off Meeting Bulan Energy & Loss 2022

Professional Development

10 Qs

Central Heating Quiz phase 2 1.4/3

Central Heating Quiz phase 2 1.4/3

Assessment

Quiz

Science

Professional Development

Medium

Created by

Daniel Edwards

Used 4+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of a pressure relief valve?

To discharge water from the heating system

To prevent corrosion in the central heating system

To regulate the flow of water in the boiler

To increase the pressure in the central heating system

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of metallic expansion joints in central heating systems?

To absorb dimensional and length changes in the pipework

To filter out sediment and sludge in the system

To regulate the temperature of the central heating water

To increase the pressure in the central heating system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the principle of an expansion vessel in a central heating system?

To accommodate the expansion of water when heated

To regulate the flow of water in the boiler

To prevent corrosion in the central heating system

To increase the pressure in the central heating system

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of an automatic bypass valve in a central heating system?

To prevent the boiler from overheating

To discharge water from the heating system

To filter out sediment and sludge in the system

To regulate the temperature of the central heating water

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main function of a magnetic corrosion central heating filter?

To remove metallic sediment from the central heating system

To regulate the flow of water in the boiler

To prevent corrosion in the central heating system

To increase the pressure in the central heating system

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should the pressure relief valve be positioned in a central heating system?

Close to the boiler

On the flow pipe

On the return pipe

On the suction side of the pump

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of expansion joint is commonly used in central heating systems?

Expansion bellows

Flexible joints

Magnetic corrosion filters

Automatic bypass valves

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What material is the membrane of an expansion vessel made of?

Neoprene rubber

Metallic alloy

Copper

PVC

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When does the automatic bypass valve open in a central heating system?

When all zone valves and thermostatic radiator valves are closed

When the boiler is turned on

When the system is low on water

When the pump is not working