Sanitary Appliances and Pipework Systems phase 2 1.6

Sanitary Appliances and Pipework Systems phase 2 1.6

Professional Development

9 Qs

quiz-placeholder

Similar activities

Fungi

Fungi

Professional Development

12 Qs

Materials

Materials

Professional Development

11 Qs

Sanitary Appliances and Pipework Systems QuizL3P2U9,1.12

Sanitary Appliances and Pipework Systems QuizL3P2U9,1.12

Professional Development

4 Qs

non-mechanical & mechanical backflow protection

non-mechanical & mechanical backflow protection

Professional Development

14 Qs

TOOLS AND MACHINES

TOOLS AND MACHINES

12th Grade - Professional Development

12 Qs

GMJ 9189 Phase 3 Cold water MCQ part 1

GMJ 9189 Phase 3 Cold water MCQ part 1

Professional Development

10 Qs

WATER & WASTEWATER QUIZ

WATER & WASTEWATER QUIZ

7th Grade - Professional Development

10 Qs

PP9 Sanitation

PP9 Sanitation

Professional Development

14 Qs

Sanitary Appliances and Pipework Systems phase 2 1.6

Sanitary Appliances and Pipework Systems phase 2 1.6

Assessment

Quiz

Science

Professional Development

Hard

Created by

Daniel Edwards

Used 2+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the expansion rate of PVCu soil pipes and waste pipes?

0.06cm/m/C

0.06mm/m/oC

0.06cm/m/oC

0.06mm/m/C

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What can happen if the expansion of PVCu pipes is not accommodated for?

Increased water pressure

Corrosion of the pipes

Decreased water flow

Pipe movement and joint leakage

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the given example, how much will the 6m run of 110mm soil pipe expand?

0.072mm

7.2mm

0.72mm

72mm

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How much expansion should be allowed for in pipe fittings to prevent joint leakage?

0.1mm

10mm

100mm

1mm

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the given example, how much will the 15m run of 110mm soil pipe expand?

3.15mm

31.5mm

315mm

0.315mm

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the 15m run of 110mm soil pipe to be fixed?

Vertically inside a residential building

Horizontally in an industrial building

Horizontally in a small commercial property

Vertically on the outside of a multi-storey building

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the negative effect of pipe movement and joint leakage?

Water damage and potential health hazards

Corrosion of the pipes

Decreased water flow

Increased water pressure

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct expansion rate for PVCu soil pipes and waste pipes?

0.06mm/m/oC

0.06cm/m/oC

0.06mm/m/C

0.06cm/m/C

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be installed to accommodate for pipe expansion?

Filters

Valves

Additional pipes

Pipe fittings