Residential Wiring Chapter 2 Quiz

Residential Wiring Chapter 2 Quiz

11th Grade

30 Qs

quiz-placeholder

Similar activities

Semester Review

Semester Review

Electrical Quiz

Electrical Quiz

R.W Chapter 6 Assessment

R.W Chapter 6 Assessment

R.W Chap.18 Quiz

R.W Chap.18 Quiz

NCCER Ch. 9 Review

NCCER Ch. 9 Review

Conductors and Cables Quiz

Conductors and Cables Quiz

Residential Wiring Chapter 2 Quiz

Residential Wiring Chapter 2 Quiz

Assessment

Quiz

Physics

11th Grade

Medium

NGSS
MS-ETS1-1, MS-ETS1-2

Standards-aligned

Created by

Kevon Kirton

Used 16+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The _________ is a scale of specified diameters and cross sections for wire sizing and is the standard wire sizing scale for the United States.

American Wire Gauge

Metric system

United States measuring system

None of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An accidental connection of a 'hot' conductor and a grounded piece of equipment or the grounded conductor is called a(n) ________.

Open circuit

Grounding conductor

Ground fault

Complete circuit

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A low resistance path, which results in a high value of current that flows around, rather than through, a circuit is called a(n) ________ circuit.

Open

Short

Grounded

Grounding

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is the ________ who has the job of approving the electrical materials used for a residential electrical installation.

Electrician

Foreman

Architect

Authority having jurisdiction

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The ________ is an organization that develops electrical equipment standards that all member groups follow when designing and producing electrical equipment.

Underwriters Laboratories

Canadian Standards Association

National Electrical Manufacturers Association

National Electrical Code®

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The National Electrical Code® requires Type NM cable to be secured no more than ________ inches from single-gang nonmetallic device boxes.

6

8

10

12

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When nonmetallic device boxes that are 2-gang or more are used, the installed Type NM cable must be secured no more than ________ inches from the box.

8

10

12

18

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?