GQ_Design

GQ_Design

Professional Development

15 Qs

quiz-placeholder

Similar activities

MASONRY

MASONRY

Professional Development

19 Qs

1995 CSI Masterformat - 03

1995 CSI Masterformat - 03

7th Grade - Professional Development

16 Qs

INDUCCIÓN ARQUITECTURA BIOCLIMÁTICA

INDUCCIÓN ARQUITECTURA BIOCLIMÁTICA

University - Professional Development

12 Qs

Structural

Structural

Professional Development

20 Qs

CH3 Means of Egress part02

CH3 Means of Egress part02

Professional Development

20 Qs

Bldg Laws- RA 9266

Bldg Laws- RA 9266

Professional Development

20 Qs

Cha_Building Tech

Cha_Building Tech

Professional Development

20 Qs

Building Materials

Building Materials

10th Grade - Professional Development

15 Qs

GQ_Design

GQ_Design

Assessment

Quiz

Architecture

Professional Development

Medium

Created by

Rov Peralta

Used 11+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the best orientation of bedroom?

North

South

East

West

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following material has the lowest thermal conductivity

Brick

Wood

Steel

Drywall

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which side of structure will be exposed to the sun for approximately 4 months

North

South

East

West

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At what stage should you consider tropical design concepts

At the very onset, during pre design stage

Anytime during the design development stage

During cintract documenation

During schematic design stage

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Masonry Chimneys for Residential Type Appliances. Masonry chimneys shall be constructed of masonry units or reinforced concrete with walls not less than_____mm thick; or of rubble stone masonry not less than 300 millimeters thick. The chimney liner shall be in accordance with this Code.

100

50

150

200

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Masonry Chimneys for Low Heat Appliances. Masonry chimneys shall be constructed of masonry units or reinforced concrete with walls not less than ___ mm thick: Except, that rubble stone masonry shall be not less than 300 millimeters thick. The chimney liner shall be in accordance with this Code.

200

100

50

150

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Under _____ of the Civil Code of the Philippines, the engineer or architect who drew up the plans and specifications for a building/structure is liable for damages if within fifteen (15) years from the completion of the building/structure, the same should collapse due to defect in the plans or specifications or defects in the ground

Article 1723

Article 1725

Article 1823

Article 1825