Refrigeration and Air Conditioning Quiz

Refrigeration and Air Conditioning Quiz

Professional Development

30 Qs

quiz-placeholder

Similar activities

Ganache, Chocolate, and Temper

Ganache, Chocolate, and Temper

University - Professional Development

25 Qs

Business Banking Quiz

Business Banking Quiz

Professional Development

25 Qs

LU1_SSO_TRACKING&REVIEW

LU1_SSO_TRACKING&REVIEW

University - Professional Development

25 Qs

Drafting by Sir AL

Drafting by Sir AL

Professional Development

30 Qs

Test - Team Thục Quyên

Test - Team Thục Quyên

Professional Development

25 Qs

Climatology

Climatology

10th Grade - Professional Development

25 Qs

QUIZ WOW 1

QUIZ WOW 1

Professional Development

25 Qs

Arlo Wire-Free

Arlo Wire-Free

Professional Development

25 Qs

Refrigeration and Air Conditioning Quiz

Refrigeration and Air Conditioning Quiz

Assessment

Quiz

Other

Professional Development

Practice Problem

Medium

Created by

Jermaine Taffe

Used 13+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which causes considerable ice build-up around a TEV?

High evaporator load

Evaporator fan failing

Defrost failing

Short of refrigerant

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which refrigerant listed below is A3?

R404a

R1234yf

R717

R290

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is used to transfer waste refrigerant from HCFC system to a storage cylinder?

Recovery unit

Vacuum pump

Reclaim unit

Oil sump pump

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What would indicate that there had been a leak on a pressure relief valve on a liquid receiver?

Excessive oil staining

Condensation on the PRV

Partial frosting on the valve

Sweating on the outside of the receiver

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a leak occurs on a service valve, where is it likely around?

The cap

The service valve key

The gland nut

The stem

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Excessive superheat across a direct expansion evaporator in a supermarket frozen food case is likely caused by:

Evaporator fans turned off

Damaged evaporator fins

Partially blocked EEV strainer

Overcharge of refrigerant

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The reference point of a Celsius thermometer is taken from?

-10 degrees C

0 degrees C

+10 degrees C

+20 degrees C

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?