Sanitation Systems QuizL3P2U9,1.10

Sanitation Systems QuizL3P2U9,1.10

Professional Development

9 Qs

quiz-placeholder

Similar activities

Reading a Ruler (Metric)

Reading a Ruler (Metric)

KG - Professional Development

10 Qs

Environmental Technology Systems Quiz

Environmental Technology Systems Quiz

Professional Development

11 Qs

LARO 21: Synergy - Building Utilities

LARO 21: Synergy - Building Utilities

Professional Development

10 Qs

ArchDes Quiz 4

ArchDes Quiz 4

KG - Professional Development

10 Qs

Rainwater System Components

Rainwater System Components

Professional Development

12 Qs

Proportion, Scale, and Balance

Proportion, Scale, and Balance

University - Professional Development

12 Qs

LARO 21: Synergy - History of Architecture

LARO 21: Synergy - History of Architecture

Professional Development

10 Qs

LARO 21: Synergy - Tropical Design

LARO 21: Synergy - Tropical Design

Professional Development

10 Qs

Sanitation Systems QuizL3P2U9,1.10

Sanitation Systems QuizL3P2U9,1.10

Assessment

Quiz

Architecture

Professional Development

Medium

Created by

Craig Boothright

Used 6+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What are the three methods of below ground drainage that can be used to discharge water from sanitary appliances?

The separate system, The combined system, The integrated system

The separate system, The partially separate system, The integrated system

The separate system, The partially separate system, The combined system

The combined system, The partially combined system, The integrated system

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main problem with the separate system of below ground drainage?

Possibility of contaminating a water course with raw sewage if the wrong connections to the system are made.

System planning can be troublesome.

Foul water drains are not flushed through during heavy rainfall.

It is extremely expensive to install.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is another name for the partially separate system?

The separate system

The integrated system

The partially combined system

The combined system

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is one of the main problems with the combined system of below ground drainage?

Foul water drains are not flushed through during heavy rainfall.

System planning can be troublesome.

It is extremely expensive to install.

During periods of heavy rain, the drainage system can become flooded.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of a soakaway drain?

To disperse rainwater run off from roof areas

To discharge waste water from sanitary appliances

To treat waste water before discharging it into the drainage system

To store rainwater for later use

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the design ratio for small soakaways serving 25m2 or less of roof area?

15mm rainfall in 20 minutes

10mm rainfall in 5 minutes

20mm rainfall in 15 minutes

5mm rainfall in 10 minutes

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should soakaways not be sited?

Within 2.5 m of a building

Where the water table is high

Near a drainage field

All of the above

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be referenced for soakaways greater than 25m2?

BS EN 752 part 4

Water Regulations

Building Regulations

Approved Document H

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the main problem with the partially separate system of below ground drainage?

Possibility of contaminating a water course with raw sewage if the wrong connections to the system are made.

Foul water drains are not flushed through during heavy rainfall.

System planning can be troublesome.

It is extremely expensive to install.