Electrical L2 8202 Mixed Mock

Electrical L2 8202 Mixed Mock

12th Grade

47 Qs

quiz-placeholder

Similar activities

Taher - Physics - electric current

Taher - Physics - electric current

9th - 12th Grade

50 Qs

Electric Currents & Circuits

Electric Currents & Circuits

11th - 12th Grade

45 Qs

Unit 7 Current Electricity Review

Unit 7 Current Electricity Review

9th - 12th Grade

43 Qs

GCSE Electricity End of Topic Test

GCSE Electricity End of Topic Test

9th - 12th Grade

50 Qs

AQA GCSE PHYSICS - ENERGY

AQA GCSE PHYSICS - ENERGY

KG - 12th Grade

52 Qs

Magnetism and AC circuit

Magnetism and AC circuit

12th Grade

50 Qs

Waves Test

Waves Test

9th - 12th Grade

50 Qs

Series and Parallel Circuits + Electrical Power 2022

Series and Parallel Circuits + Electrical Power 2022

9th - 12th Grade

43 Qs

Electrical L2 8202 Mixed Mock

Electrical L2 8202 Mixed Mock

Assessment

Quiz

Physics

12th Grade

Hard

Created by

Connor Jenkins

Used 7+ times

FREE Resource

47 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the first action to take after discovering an accidental fire on a construction site?

Ring the HSE.

Raise the alarm.

Smother the flames.

Find an extinguisher.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which instrument is required to carry out Safe Isolation?

Loop Impedance Tester.

Low Resistance Ohmmeter.

Approved Voltage Indicator.

Insulation Resistance Tester.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which substance would require specialist licenced removal if found during a building demolition?

Cement.

Gypsum.

Plywood.

Asbestos.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What unit is equivalent to V x 10^-3?

MV

kV

mV

μV

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which has the lowest resistivity?

Lead.

Steel.

Copper.

Aluminium.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What would be the nominal voltage of a battery made up of twenty-five 1.2 V cells when connected in series?

1.2 V

12 V

30 V

48 V

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must as a minimum be provided at the origin of all single-phase installations?

Single-pole main switch

Double-pole main switch.

Triple-pole main switch.

Quadruple-pole main switch

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?