Search Header Logo

EPA Section 608 type 2

Authored by c Romanski

Science

12th Grade

NGSS covered

Used 75+ times

EPA Section 608 type 2
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What will back-seating a suction shutoff valve close?

Suction line and compressor port

Compressor and gauge port

Compressor port

Gauge port

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the easiest way to check the type of refrigerant used in a packaged rooftop unit

The unit nameplate

The refrigerant cylinder

Ohms law

Looking at the incoming voltage.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When trying to figure out the leak rate calculations on a package unit. What information can you use?

Charge stated on name plate

Total length of piping and system components

Recovery cylinder weight

Compressor horse power divided by amperage. In addition to filter dryer diameter.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Air-conditioning appliances used to supply cooling in order to control heat and/or humidity in occupied facilities is defined by EPA as Comfort Cooling. Which facility's are included in this category?

Residential, office, and commercial

Big y freezers

Walmart walk-in coolers

House hold "domestic refrigerators"

Tags

NGSS.MS-PS3-3

NGSS.MS-PS3-4

5.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

Which of the following repairs would always be considered 'major' under EPA's regulation?

Replacement of an evaporator coil.

Replacement of a filter-drier.

Replacement of a Schrader valve core.

Replacement of a condenser fan motor.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Before making a major repair, technicians must evacuate an appliance or component containing more than 200 pounds of R-410A to which of the following levels?

0 psig

25 mm Hg absolute

10 inches of Hg vacuum

15 inches of Hg vacuum

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A cold storage warehouse chooses not to repair an appliance containing R-22 that is leaking above the threshold rate. How long can the facility continue to operate that appliance before it must be retrofitted or retired, assuming no extensions apply?

1 month

9 months

12 months

24 months

Tags

NGSS.HS-LS2-7

NGSS.HS-ESS3-4

NGSS.HS-ETS1-3

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?