EPA Section 608 type 2

EPA Section 608 type 2

12th Grade

30 Qs

quiz-placeholder

Similar activities

EPA 609

EPA 609

10th Grade - University

25 Qs

EPA 608 Type III

EPA 608 Type III

9th Grade - University

25 Qs

HVAC Hydronic Heat

HVAC Hydronic Heat

3rd Grade - University

25 Qs

Brake System

Brake System

12th Grade - University

25 Qs

Pneumatic Systems

Pneumatic Systems

8th Grade - University

25 Qs

EPA 608 Type 1

EPA 608 Type 1

12th Grade - University

25 Qs

HVAC Quiz

HVAC Quiz

12th Grade - University

25 Qs

EPA 608 Type I

EPA 608 Type I

9th - 12th Grade

25 Qs

EPA Section 608 type 2

EPA Section 608 type 2

Assessment

Quiz

Science

12th Grade

Medium

NGSS
HS-LS2-7, MS-PS3-3, MS-PS3-4

+2

Standards-aligned

Created by

c Romanski

Used 67+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What will back-seating a suction shutoff valve close?

Suction line and compressor port

Compressor and gauge port

Compressor port

Gauge port

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the easiest way to check the type of refrigerant used in a packaged rooftop unit

The unit nameplate

The refrigerant cylinder

Ohms law

Looking at the incoming voltage.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When trying to figure out the leak rate calculations on a package unit. What information can you use?

Charge stated on name plate

Total length of piping and system components

Recovery cylinder weight

Compressor horse power divided by amperage. In addition to filter dryer diameter.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Air-conditioning appliances used to supply cooling in order to control heat and/or humidity in occupied facilities is defined by EPA as Comfort Cooling. Which facility's are included in this category?

Residential, office, and commercial

Big y freezers

Walmart walk-in coolers

House hold "domestic refrigerators"

Tags

NGSS.MS-PS3-3

NGSS.MS-PS3-4

5.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

Which of the following repairs would always be considered 'major' under EPA's regulation?

Replacement of an evaporator coil.

Replacement of a filter-drier.

Replacement of a Schrader valve core.

Replacement of a condenser fan motor.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Before making a major repair, technicians must evacuate an appliance or component containing more than 200 pounds of R-410A to which of the following levels?

0 psig

25 mm Hg absolute

10 inches of Hg vacuum

15 inches of Hg vacuum

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A cold storage warehouse chooses not to repair an appliance containing R-22 that is leaking above the threshold rate. How long can the facility continue to operate that appliance before it must be retrofitted or retired, assuming no extensions apply?

1 month

9 months

12 months

24 months

Tags

NGSS.HS-ESS3-4

NGSS.HS-ETS1-3

NGSS.HS-LS2-7

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?