IS 13920 Reinforced Concrete Structures Quiz

IS 13920 Reinforced Concrete Structures Quiz

Professional Development

15 Qs

quiz-placeholder

Similar activities

Massing in Architectural Design

Massing in Architectural Design

University - Professional Development

11 Qs

1995 CSI Masterformat - 02

1995 CSI Masterformat - 02

7th Grade - Professional Development

16 Qs

IS 13920 Reinforced Concrete Structures Quiz

IS 13920 Reinforced Concrete Structures Quiz

Assessment

Quiz

Architecture

Professional Development

Practice Problem

Medium

Created by

DANIEL V

Used 3+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of ductile detailing in reinforced concrete structures according to IS 13920?

Increase construction cost

Enhance structural strength and ductility

Reduce material usage

Improve aesthetic appearance

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In ductile detailing, what does IS 13920 recommend for maintaining ductility in the structure during seismic events?

Increasing concrete strength

Increasing beam spans

Providing seismic links and confining reinforcement

Reducing column sizes

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In seismic zones, IS 13920 recommends detailing of reinforcement to ensure:

Brittle failure

Ductile failure

No failure

Fatigue failure

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of providing transverse reinforcement in beams as per IS 13920?

Increase axial load capacity

Improve fire resistance

Enhance shear strength and ductility

Reduce deflection

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As per IS 13920, what is the recommended minimum grade of concrete for earthquake-resistant structures?

M15

M20

M25

M30

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of providing confinement reinforcement in the critical regions of a column as per IS 13920?

Enhance column stiffness

Increase column height

Improve column aesthetics

Confer ductility to the column under axial loads

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to IS 13920, what is the minimum diameter of longitudinal reinforcement bars used in seismic-resistant columns?

6 mm

10 mm

12 mm

16 mm

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?