Monthly JATC 1/24

Monthly JATC 1/24

Professional Development

10 Qs

quiz-placeholder

Similar activities

UTILITIES-QUIZ#3 (WATER DISTRUBUTION)

UTILITIES-QUIZ#3 (WATER DISTRUBUTION)

Professional Development

15 Qs

National Building Code of the Philippines Quiz

National Building Code of the Philippines Quiz

Professional Development

10 Qs

PHIL.CHURCH(WIN)

PHIL.CHURCH(WIN)

Professional Development

15 Qs

LARO 21: Synergy - Building Utilities

LARO 21: Synergy - Building Utilities

Professional Development

10 Qs

L3P3U7lo3

L3P3U7lo3

Professional Development

10 Qs

Rainwater Systems QuizL3P2U8,1.2

Rainwater Systems QuizL3P2U8,1.2

Professional Development

10 Qs

Rainwater Systems Quiz phase2 lo1.2

Rainwater Systems Quiz phase2 lo1.2

Professional Development

8 Qs

Div 5 - Metal

Div 5 - Metal

Professional Development

12 Qs

Monthly JATC 1/24

Monthly JATC 1/24

Assessment

Quiz

Architecture

Professional Development

Hard

Created by

Robert Starcher

Used 13+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

15 mins • 10 pts

NFPA ____ is the Standard for the Installation of Stationary Pumps for Fire Protection.

20

25

14

13

2.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

A local water flow alarm shall be provided on every sprinkler system having more than ___ sprinklers.

3.

MULTIPLE CHOICE QUESTION

15 mins • 10 pts

For sprinklers installed around vertical openings, the sprinklers shall be spaced not more than 6 ft apart and placed ___________________ from the draft stop on the side away from the opening.

0" to 6"

18" to 24"

6" to 12"

12" to 18"

4.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

Drive screws shall be used only in a________________ position as in the side of a beam and only for 2 in. (50 mm) or smaller pipe.

5.

MULTIPLE SELECT QUESTION

15 mins • 10 pts

Where the existence of microbes and conditions are found that contribute to MIC, a plan shall be developed to treat the system using one of the following methods;

Install a water pipe that will not be affected by the MIC microbes.

Thoroughly flush all piping.

Leave system drained for a month and refill with fresh water

Completely replace the system piping.

6.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

NFPA _____ is the Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems.

7.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

The minimum temperature rating of ceiling sprinklers in general storage, rack storage, rubber tire storage, roll paper storage, and baled cotton storage applications shall be ___°F.