Most electrical problems with an electric motor are ____.

short circuited windings. open windings, and grounded windings
short circuited windings, closed windings, and grounded windings
all of the above
none of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A technician needs to check a single-phase compressor. He labels the three terminals "A," "B," and "C" and takes resistance readings of the windings. He reads 10 ohms from "A" to "B," infinity from "B" to "C," and infinity from "C" to "A." Identify the terminals.

Cannot identify terminals: open winding
Cannot identify terminals: winding grounded
A: common B: start C: run
A: start B: run C: common

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Technician "A" says that while checking the windings of a compressor, a reading of 10 ohms or less from the common terminal to ground indicates that the motor is okay. Technician "B" says that the resistance of the start winding should always be less than the resistance of the run winding. Which of the following statements is correct?

Technician "A" is incorrect. Technician "B" is incorrect.
Technician "A" is correct. Technician "B" is correct.
Technician "A" is correct. Technician "B" is incorrect.
Technician "A" is incorrect. Technician "B" is correct.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An open winding in an electric motor means that ____.

a wire in a winding is broken
the winding is making contact with the motor frame
one winding is making contact with another winding
the centrifugal switch to the start winding is open

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Technician "A" says that a shorted winding will result in an increased current flow through the winding. Technician "B" says that if a motor is to be replaced, a motor with a lower horsepower rating should always be used. Which of the following statements is correct?

Technician "A" is correct. Technician "B" is incorrect.
Technician "A" is correct. Technician "B" is correct.
Technician "A" is incorrect. Technician "B" is correct.
Technician "A" is incorrect. Technician "B" is incorrect.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the resistance of the run winding decreases, the ____.

motor will draw too much current while it is running
motor probably will not start
centrifugal starting switch will not start the motor
load on the motor is probably too great

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a condenser fan motor grounds out, it will usually ____.

trip a circuit breaker to shut off the unit
keep running as the current is only going to ground
run a little faster because the amperage draw will increase
cause the evaporator to ice up

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?