IDA-201 Unit 20

IDA-201 Unit 20

30 Qs

quiz-placeholder

Similar activities

Pneumatics & Motor Sharing Practice Quiz

Pneumatics & Motor Sharing Practice Quiz

8th Grade - University

30 Qs

HHB 3.4 Part 1 Neurons, Neurotransmitters & Synapses

HHB 3.4 Part 1 Neurons, Neurotransmitters & Synapses

11th Grade

31 Qs

Chapter 1 Introduction to the Automobile

Chapter 1 Introduction to the Automobile

9th - 12th Grade

25 Qs

Vocational Auto Final

Vocational Auto Final

KG - University

29 Qs

IMI Level 3 AE06 Electrical Principles - Light Vehicle Maintenance - 2 of 3

IMI Level 3 AE06 Electrical Principles - Light Vehicle Maintenance - 2 of 3

KG - University

35 Qs

IDA-201 Unit 19

IDA-201 Unit 19

KG - University

30 Qs

IDA-201 Unit 20

IDA-201 Unit 20

Assessment

Quiz

others

Easy

Created by

Timothy McIntyre

Used 12+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Most electrical problems with an electric motor are ____.
short circuited windings. open windings, and grounded windings
short circuited windings, closed windings, and grounded windings
all of the above
none of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A technician needs to check a single-phase compressor. He labels the three terminals "A," "B," and "C" and takes resistance readings of the windings. He reads 10 ohms from "A" to "B," infinity from "B" to "C," and infinity from "C" to "A." Identify the terminals.
Cannot identify terminals: open winding
Cannot identify terminals: winding grounded
A: common B: start C: run
A: start B: run C: common

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Technician "A" says that while checking the windings of a compressor, a reading of 10 ohms or less from the common terminal to ground indicates that the motor is okay. Technician "B" says that the resistance of the start winding should always be less than the resistance of the run winding. Which of the following statements is correct?
Technician "A" is incorrect. Technician "B" is incorrect.
Technician "A" is correct. Technician "B" is correct.
Technician "A" is correct. Technician "B" is incorrect.
Technician "A" is incorrect. Technician "B" is correct.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An open winding in an electric motor means that ____.
a wire in a winding is broken
the winding is making contact with the motor frame
one winding is making contact with another winding
the centrifugal switch to the start winding is open

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Technician "A" says that a shorted winding will result in an increased current flow through the winding. Technician "B" says that if a motor is to be replaced, a motor with a lower horsepower rating should always be used. Which of the following statements is correct?
Technician "A" is correct. Technician "B" is incorrect.
Technician "A" is correct. Technician "B" is correct.
Technician "A" is incorrect. Technician "B" is correct.
Technician "A" is incorrect. Technician "B" is incorrect.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the resistance of the run winding decreases, the ____.
motor will draw too much current while it is running
motor probably will not start
centrifugal starting switch will not start the motor
load on the motor is probably too great

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a condenser fan motor grounds out, it will usually ____.
trip a circuit breaker to shut off the unit
keep running as the current is only going to ground
run a little faster because the amperage draw will increase
cause the evaporator to ice up