Phase 2 Re-cap & Revision

Phase 2 Re-cap & Revision

Professional Development

60 Qs

quiz-placeholder

Similar activities

movement of body

movement of body

University - Professional Development

65 Qs

2ND YEAR INTEGRATED SCIENCE EXAM PART 1

2ND YEAR INTEGRATED SCIENCE EXAM PART 1

Professional Development

55 Qs

La Calidad en la Oficina de Farmacia

La Calidad en la Oficina de Farmacia

Professional Development

60 Qs

Energy, Power, & Transportation

Energy, Power, & Transportation

Professional Development

56 Qs

Calor y Temperatura

Calor y Temperatura

Professional Development

65 Qs

Pathophysiology Exam 1 Given Q's T/F (Blood)

Pathophysiology Exam 1 Given Q's T/F (Blood)

Professional Development

57 Qs

Science 7 Unit B Section 1.0

Science 7 Unit B Section 1.0

1st Grade - Professional Development

57 Qs

TAO UD 2 Cavidad Bucal y Estructura Dentaria

TAO UD 2 Cavidad Bucal y Estructura Dentaria

Professional Development

60 Qs

Phase 2 Re-cap & Revision

Phase 2 Re-cap & Revision

Assessment

Quiz

Science

Professional Development

Practice Problem

Medium

Created by

Rob Anderson

Used 7+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

60 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An RPZ valve should be installed with

an isolating valve upstream of the RPZ valve

an isolating valve downstream of the RPZ valve

an isolating valve both upstream and downstream of the RPZ valve

no isolating valves

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In which one of the following fluid categories does the domestic water from a washbasin fall

Category 1

Category 2

Category 3

Category 4

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the component labelled A in the diagram

Expansion cistern

Break cistern

Duplicate pumps

Circulating pumps

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Under Regulation 5 of the Water Regulations, the water undertaker must be informed when which one of the following operations is carried out?

Installation of a pump drawing more than 12 litres per minute

Installation of a bidet without an ascending spray or flexible hose

Installation of a bath with a capacity of fewer than 230 litres

Installation of an RPZ valve to protect against a category 2 fluid

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The type of non-mechanical backflow prevention used on a domestic washbasin is known as

AUK 1

AUK 2

AUK 3

AUK 4

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following items of legislation covers the requirements for the hydraulic testing of cold water pipe lines

Water Byelaws (England 2004)

British Standards 5449

Water Supply (Water Fittings) Regulations 1999

Building Regulations Part G (P in Northern Ireland)

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following mechanical backflow prevention devices would be used when installing a replacement hose union bib tap

BA

HUK1

HA

HC

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?